Calibrated Low-Order Transient Thermal and Flow Models for Robust Test Facility Design

Abstract
This paper describes an upgrade to high temperature operation of the Engine Component AeroThermal (ECAT) facility, an established engine-parts facility at the University of Oxford. The facility is used for high-TRL research and development, new technology demonstration, and for component...