Institutional Tuberculosis Transmission. Controlled Trial of Upper Room Ultraviolet Air Disinfection: A Basis for New Dosing Guidelines
- 15 August 2015
- journal article
- Published by American Thoracic Society in American Journal of Respiratory and Critical Care Medicine
- Vol. 192 (4), 477-484
- https://doi.org/10.1164/rccm.201501-0060oc
Abstract
Transmission is driving the global tuberculosis epidemic, especially in congregate settings. Worldwide, natural ventilation is the most common means of air disinfection, but it is inherently unreliable and of limited use in cold climates. Upper room germicidal ultraviolet (UV) air disinfection with air mixing has been shown to be highly effective, but improved evidence-based dosing guidelines are needed. To test the efficacy of upper room germicidal air disinfection with air mixing to reduce tuberculosis transmission under real hospital conditions, and to define the application parameters responsible as a basis for proposed new dosing guidelines. Over an exposure period of 7 months, 90 guinea pigs breathed only untreated exhaust ward air, and another 90 guinea pigs breathed only air from the same six-bed tuberculosis ward on alternate days when upper room germicidal air disinfection was turned on throughout the ward. The tuberculin skin test conversion rates (>6 mm) of the two chambers were compared. The hazard ratio for guinea pigs in the control chamber converting their skin test to positive was 4.9 (95% confidence interval, 2.8-8.6), with an efficacy of approximately 80%. Upper room germicidal UV air disinfection with air mixing was highly effective in reducing tuberculosis transmission under hospital conditions. These data support using either a total fixture output (rather than electrical or UV lamp wattage) of 15-20 mW/m(3) total room volume, or an average whole-room UV irradiance (fluence rate) of 5-7 μW/cm(2), calculated by a lighting computer-assisted design program modified for UV use.This publication has 29 references indexed in Scilit:
- Surgical Face Masks Worn by Patients with Multidrug-Resistant TuberculosisAmerican Journal of Respiratory and Critical Care Medicine, 2012
- Natural infection of guinea pigs exposed to patients with highly drug-resistant tuberculosisTuberculosis, 2011
- Upper-Room Ultraviolet Light and Negative Air Ionization to Prevent Tuberculosis TransmissionPLoS Medicine, 2009
- Inactivation of Poxviruses by Upper-Room UVC Light in a Simulated Hospital Room EnvironmentPLOS ONE, 2008
- Fundamental Factors Affecting Upper-Room Ultraviolet Germicidal Irradiation—Part I. ExperimentalJournal of Occupational and Environmental Hygiene, 2007
- Fundamental Factors Affecting Upper-Room Ultraviolet Germicidal Irradiation—Part II. Predicting EffectivenessJournal of Occupational and Environmental Hygiene, 2007
- Efficacy of ultraviolet germicidal irradiation of upper-room air in inactivating airborne bacterial spores and mycobacteria in full-scale studiesAtmospheric Environment, 2003
- A New Perspective on John Snow's Communicable Disease TheoryAmerican Journal of Epidemiology, 1995
- Fans, Filters, or Rays? Pros and Cons of the Current Environmental Tuberculosis Control TechnologiesInfection Control & Hospital Epidemiology, 1993
- Positive-Hole Correction of Multiple-Jet Impactors for Collecting Viable MicroorganismsAihaj Journal, 1989