Fundamental Factors Affecting Upper-Room Ultraviolet Germicidal Irradiation—Part I. Experimental
- 26 March 2007
- journal article
- research article
- Published by Taylor & Francis Ltd in Journal of Occupational and Environmental Hygiene
- Vol. 4 (5), 321-331
- https://doi.org/10.1080/15459620701271693
Abstract
The objective of this research was to study the factors that relate to the effectiveness of upper-room ultraviolet germicidal irradiation for inactivating airborne microorganisms. The work was conducted in a room-sized chamber designed and furnished for investigations of this nature. Nebulized Serratia marcescens, Bacillus subtilis spores, and vaccinia virus were used as test aerosols. Most data were collected from steady-state experiments comparing the number of viable organisms in the chamber air remaining with UV lamps turned on to the number with UV lamps turned off, but some decay experiments were conducted to compare the two methods. UV power level had a strong influence but was fully effective only in the presence of air mixing that produced vigorous vertical air currents. A conclusion of the study is that an upper-room ultraviolet installation is a complex system that requires careful integration of UV luminaires, UV power, and room ventilation arrangements.Keywords
This publication has 6 references indexed in Scilit:
- Monitoring Human Exposures to Upper-Room Germicidal Ultraviolet IrradiationJournal of Occupational and Environmental Hygiene, 2005
- The Growing Burden of TuberculosisArchives of Internal Medicine, 2003
- The application of ultraviolet germicidal irradiation to control transmission of airborne disease: bioterrorism countermeasurePublic Health Reports, 2003
- Dosimetry of Room‐Air Germicidal (254 nm) Radiation Using Spherical ActinometryPhotochemistry and Photobiology, 1999
- Characterization of Ultraviolet Upper Room Air Disinfection DevicesAihaj Journal, 1999
- Room Air Disinfection by Ultraviolet Irradiation of Upper AirArchives of environmental health, 1971