Inactivation of Poxviruses by Upper-Room UVC Light in a Simulated Hospital Room Environment
Open Access
- 10 September 2008
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 3 (9), e3186
- https://doi.org/10.1371/journal.pone.0003186
Abstract
In the event of a smallpox outbreak due to bioterrorism, delays in vaccination programs may lead to significant secondary transmission. In the early phases of such an outbreak, transmission of smallpox will take place especially in locations where infected persons may congregate, such as hospital emergency rooms. Air disinfection using upper-room 254 nm (UVC) light can lower the airborne concentrations of infective viruses in the lower part of the room, and thereby control the spread of airborne infections among room occupants without exposing occupants to a significant amount of UVC. Using vaccinia virus aerosols as a surrogate for smallpox we report on the effectiveness of air disinfection, via upper-room UVC light, under simulated real world conditions including the effects of convection, mechanical mixing, temperature and relative humidity. In decay experiments, upper-room UVC fixtures used with mixing by a conventional ceiling fan produced decreases in airborne virus concentrations that would require additional ventilation of more than 87 air changes per hour. Under steady state conditions the effective air changes per hour associated with upper-room UVC ranged from 18 to 1000. The surprisingly high end of the observed range resulted from the extreme susceptibility of vaccinia virus to UVC at low relative humidity and use of 4 UVC fixtures in a small room with efficient air mixing. Increasing the number of UVC fixtures or mechanical ventilation rates resulted in greater fractional reduction in virus aerosol and UVC effectiveness was higher in winter compared to summer for each scenario tested. These data demonstrate that upper-room UVC has the potential to greatly reduce exposure to susceptible viral aerosols. The greater survival at baseline and greater UVC susceptibility of vaccinia under winter conditions suggest that while risk from an aerosol attack with smallpox would be greatest in winter, protective measures using UVC may also be most efficient at this time. These data may also be relevant to influenza, which also has improved aerosol survival at low RH and somewhat similar sensitivity to UVC.Keywords
This publication has 18 references indexed in Scilit:
- 2007 Guideline for Isolation Precautions: Preventing Transmission of Infectious Agents in Health Care SettingsAmerican Journal of Infection Control, 2007
- Characterization of UVC Light Sensitivity of Vaccinia VirusApplied and Environmental Microbiology, 2007
- Fundamental Factors Affecting Upper-Room Ultraviolet Germicidal Irradiation—Part I. ExperimentalJournal of Occupational and Environmental Hygiene, 2007
- Fundamental Factors Affecting Upper-Room Ultraviolet Germicidal Irradiation—Part II. Predicting EffectivenessJournal of Occupational and Environmental Hygiene, 2007
- Monitoring Human Exposures to Upper-Room Germicidal Ultraviolet IrradiationJournal of Occupational and Environmental Hygiene, 2005
- The application of ultraviolet germicidal irradiation to control transmission of airborne disease: bioterrorism countermeasurePublic Health Reports, 2003
- Efficacy of ultraviolet germicidal irradiation of upper-room air in inactivating airborne bacterial spores and mycobacteria in full-scale studiesAtmospheric Environment, 2003
- Influence of relative humidity on particle size and UV sensitivity of Serratia marcescens and Mycobacterium bovis BCG aerosolsTubercle and Lung Disease, 2000
- A Multi-Zone Model Evaluation of the Efficacy of Upper-Room Air Ultraviolet Germicidal IrradiationApplied Occupational and Environmental Hygiene, 1999
- Airborne micro-organisms: survival tests with four virusesEpidemiology and Infection, 1961