96‐Channel receive‐only head coil for 3 Tesla: Design optimization and evaluation
Open Access
- 21 July 2009
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 62 (3), 754-762
- https://doi.org/10.1002/mrm.22028
Abstract
The benefits and challenges of highly parallel array coils for head imaging were investigated through the development of a 3T receive‐only phased‐array head coil with 96 receive elements constructed on a close‐fitting helmet‐shaped former. We evaluated several designs for the coil elements and matching circuitry, with particular attention to sources of signal‐to‐noise ratio (SNR) loss, including various sources of coil loading and coupling between the array elements. The SNR and noise amplification (g‐factor) in accelerated imaging were quantitatively evaluated in phantom and human imaging and compared to a 32‐channel array built on an identical helmet‐shaped former and to a larger commercial 12‐channel head coil. The 96‐channel coil provided substantial SNR gains in the distal cortex compared to the 12‐ and 32‐channel coils. The central SNR for the 96‐channel coil was similar to the 32‐channel coil for optimum SNR combination and 20% lower for root‐sum‐of‐squares combination. There was a significant reduction in the maximum g‐factor for 96 channels compared to 32; for example, the 96‐channel maximum g‐factor was 65% of the 32‐channel value for acceleration rate 4. The performance of the array is demonstrated in highly accelerated brain images. Magn Reson Med, 2009.Keywords
This publication has 21 references indexed in Scilit:
- 128‐channel body MRI with a flexible high‐density receiver‐coil arrayJournal of Magnetic Resonance Imaging, 2008
- A 128‐channel receive‐only cardiac coil for highly accelerated cardiac MRI at 3 TeslaMagnetic Resonance in Medicine, 2008
- 32‐channel 3 Tesla receive‐only phased‐array head coil with soccer‐ball element geometryMagnetic Resonance in Medicine, 2006
- Toward single breath‐hold whole‐heart coverage coronary MRA using highly accelerated parallel imaging with a 32‐channel MR systemMagnetic Resonance in Medicine, 2006
- Image reconstruction in SNR units: A general method for SNR measurement†Magnetic Resonance in Medicine, 2005
- Practical approaches to the evaluation of signal‐to‐noise ratio performance with parallel imaging: Application with cardiac imaging and a 32‐channel cardiac coilMagnetic Resonance in Medicine, 2005
- Highly parallel volumetric imaging with a 32‐element RF coil arrayMagnetic Resonance in Medicine, 2004
- Electrodynamics and ultimate SNR in parallel MR imagingMagnetic Resonance in Medicine, 2004
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Design of Matching Networks for Low Noise PreamplifiersMagnetic Resonance in Medicine, 1995