A 128‐channel receive‐only cardiac coil for highly accelerated cardiac MRI at 3 Tesla
Open Access
- 27 May 2008
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 59 (6), 1431-1439
- https://doi.org/10.1002/mrm.21598
Abstract
A 128‐channel receive‐only array coil is described and tested for cardiac imaging at 3T. The coil is closely contoured to the body with a “clam‐shell” geometry with 68 posterior and 60 anterior elements, each 75 mm in diameter, and arranged in a continuous overlapped array of hexagonal symmetry to minimize nearest neighbor coupling. Signal‐to‐noise ratio (SNR) and noise amplification for parallel imaging (G‐factor) were evaluated in phantom and volunteer experiments. These results were compared to those of commercially available 24‐channel and 32‐channel coils in routine use for cardiac imaging. The in vivo measurements with the 128‐channel coil resulted in SNR gains compared to the 24‐channel coil (up to 2.2‐fold in the apex). The 128‐ and 32‐channel coils showed similar SNR in the heart, likely dominated by the similar element diameters of these coils. The maximum G‐factor values were up to seven times better for a seven‐fold acceleration factor (R = 7) compared to the 24‐channel coil and up to two‐fold improved compared to the 32‐channel coil. The ability of the 128‐channel coil to facilitate highly accelerated cardiac imaging was demonstrated in four volunteers using acceleration factors up to seven‐fold (R = 7) in a single spatial dimension. Magn Reson Med 59:1431–1439, 2008.Keywords
This publication has 14 references indexed in Scilit:
- Highly accelerated imaging of cardiac function using a 32 channel cardiac phased array at 3 TRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2007
- 32‐channel 3 Tesla receive‐only phased‐array head coil with soccer‐ball element geometryMagnetic Resonance in Medicine, 2006
- Parallel imaging in cardiovascular MRI: methods and applicationsNMR in Biomedicine, 2006
- Cardiac CINE MR imaging with a 32‐channel cardiac coil and parallel imaging: Impact of acceleration factors on image quality and volumetric accuracyJournal of Magnetic Resonance Imaging, 2005
- 64-channel array coil for single echo acquisition magnetic resonance imagingMagnetic Resonance in Medicine, 2005
- Analysis of wave behavior in lossy dielectric samples at high fieldMagnetic Resonance in Medicine, 2002
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Proton spectroscopic imaging of the human brain using phased array detectorsMagnetic Resonance in Medicine, 1995
- Volume imaging with MR phased arraysMagnetic Resonance in Medicine, 1991
- The NMR phased arrayMagnetic Resonance in Medicine, 1990