128‐channel body MRI with a flexible high‐density receiver‐coil array
- 28 October 2008
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 28 (5), 1219-1225
- https://doi.org/10.1002/jmri.21463
Abstract
Purpose To determine whether the promise of high‐density many‐coil MRI receiver arrays for enabling highly accelerated parallel imaging can be realized in practice. Materials and Methods A 128‐channel body receiver‐coil array and custom MRI system were developed. The array comprises two clamshells containing 64 coils each, with the posterior array built to maximize signal‐to‐noise ratio (SNR) and the anterior array design incorporating considerations of weight and flexibility as well. Phantom imaging and human body imaging were performed using a variety of reduction factors and 2D and 3D pulse sequences. Results The ratio of SNR relative to a 32‐element array of similar footprint was 1.03 in the center of an elliptical loading phantom and 1.7 on average in the outer regions. Maximum g‐factors dropped from 5.5 (for 32 channels) to 2.0 (for 128 channels) for 4 × 4 acceleration and from 25 to 3.3 for 5 × 5 acceleration. Residual aliasing artifacts for a right/left (R/L) reduction factor of 8 in human body imaging were significantly reduced relative to the 32‐channel array. Conclusion MRI with a large number of receiver channels enables significantly higher acceleration factors for parallel imaging and improved SNR, provided losses from the coils and electronics are kept negligible. J. Magn. Reson. Imaging 2008;28:1219–1225.Keywords
This publication has 14 references indexed in Scilit:
- Fast spin echo sequences with very long echo trains: Design of variable refocusing flip angle schedules and generation of clinical T2 contrastMagnetic Resonance in Medicine, 2006
- 64-channel array coil for single echo acquisition magnetic resonance imagingMagnetic Resonance in Medicine, 2005
- Large field‐of‐view real‐time MRI with a 32‐channel systemMagnetic Resonance in Medicine, 2004
- Highly parallel volumetric imaging with a 32‐element RF coil arrayMagnetic Resonance in Medicine, 2004
- Electrodynamics and ultimate SNR in parallel MR imagingMagnetic Resonance in Medicine, 2004
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- Design of a SENSE‐optimized high‐sensitivity MRI receive coil for brain imagingMagnetic Resonance in Medicine, 2002
- A generalized approach to parallel magnetic resonance imagingMedical Physics, 2001
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- The NMR phased arrayMagnetic Resonance in Medicine, 1990