Evaluation of the Filtration Performance of NIOSH-Approved N95 Filtering Facepiece Respirators by Photometric and Number-Based Test Methods
- 1 January 2011
- journal article
- research article
- Published by Taylor & Francis Ltd in Journal of Occupational and Environmental Hygiene
- Vol. 8 (1), 23-30
- https://doi.org/10.1080/15459624.2010.515556
Abstract
N95 particulate filtering facepiece respirators are certified by measuring penetration levels photometrically with a presumed severe case test method using charge neutralized NaCl aerosols at 85 L/min. However, penetration values obtained by photometric methods have not been compared with count-based methods using contemporary respirators composed of electrostatic filter media and challenged with both generated and ambient aerosols. To better understand the effects of key test parameters (e.g., particle charge, detection method), initial penetration levels for five N95 model filtering facepiece respirators were measured using NaCl aerosols with the aerosol challenge and test equipment employed in the NIOSH respirator certification method (photometric) and compared with an ultrafine condensation particle counter method (count based) for the same NaCl aerosols as well as for ambient room air particles. Penetrations using the NIOSH test method were several-fold less than the penetrations obtained by the ultrafine condensation particle counter for NaCl aerosols as well as for room particles indicating that penetration measurement based on particle counting offers a more difficult challenge than the photometric method, which lacks sensitivity for particles < 100 nm. All five N95 models showed the most penetrating particle size around 50 nm for room air particles with or without charge neutralization, and at 200 nm for singly charged NaCl monodisperse particles. Room air with fewer charged particles and an overwhelming number of neutral particles contributed to the most penetrating particle size in the 50 nm range, indicating that the charge state for the majority of test particles determines the MPPS. Data suggest that the NIOSH respirator certification protocol employing the photometric method may not be a more challenging aerosol test method. Filter penetrations can vary among workplaces with different particle size distributions, which suggests the need for the development of new or revised “more challenging” aerosol test methods for NIOSH certification of respirators.Keywords
This publication has 22 references indexed in Scilit:
- Nanoparticle Emission Assessment Technique (NEAT) for the Identification and Measurement of Potential Inhalation Exposure to Engineered Nanomaterials—Part B: Results from 12 Field StudiesJournal of Occupational and Environmental Hygiene, 2010
- Potential for Occupational Exposure to Engineered Carbon-Based Nanomaterials in Environmental Laboratory StudiesEnvironmental Health Perspectives, 2010
- N95 and P100 Respirator Filter Efficiency Under High Constant and Cyclic FlowJournal of Occupational and Environmental Hygiene, 2008
- Filtration Performance of NIOSH-Approved N95 and P100 Filtering Facepiece Respirators Against 4 to 30 Nanometer-Size NanoparticlesJournal of Occupational and Environmental Hygiene, 2008
- Manikin-Based Performance Evaluation of N95 Filtering-Facepiece Respirators Challenged with NanoparticlesThe Annals of Occupational Hygiene, 2005
- Performance of N95 Respirators: Filtration Efficiency for Airborne Microbial and Inert ParticlesAihaj Journal, 1998
- “Worst Case” Aerosol Testing Parameters: I. Sodium Chloride and Dioctyl Phthalate Aerosol Filter Efficiency as a Function of Particle Size and Flow RateAihaj Journal, 1989
- Effect of Charging State of Particles on Electret FiltrationAerosol Science and Technology, 1987
- Respirator Filtration Efficiency TestingPublished by ASTM International ,1986
- MEASUREMENTS OF ELECTRIC CHARGE FOR WORKPLACE AEROSOLSThe Annals of Occupational Hygiene, 1985