Digital planning of high tibial osteotomy. Interrater reliability by using two different software
- 7 July 2012
- journal article
- research article
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 21 (1), 189-196
- https://doi.org/10.1007/s00167-012-2114-3
Abstract
The purpose of the study was to determine the interrater reliability as well as the correlation of mediCAD® and PreOPlan® in deformity analysis and digital planning of osteotomies. Digital radiographs were obtained from 81 patients planned to undergo an open wedge high tibial osteotomy. The JPEG files of the radiographs were imported to landmark-based software. Deformity analysis and planning of correction were performed by 1 experienced and 2 unexperienced observers. Osteotomy planning was aimed at correction to the predefined mechanical tibiofemoral angle of 3° valgus leg alignment. The interrater reliability of measurements was assessed using intraclass correlation coefficients (ICCs) and the confidence interval. The ICC of PreOPlan® was from 0.841 (mechanical lateral distal femur angle) to 0.993 (wedge-angle) and from 0.896 (joint line convergence angle) to 0.995 (mechanical tibiofemoral angle) of mediCAD®. The ICC of height of wedge-base was 0.979 with PreOPlan® and 0.969 with mediCAD®. Comparing PreOPlan® and mediCAD®, the ICC of the height of wedge-base of the observers was 0.966, 0.956 and 0.969, respectively. The results show a high interrater reliability of digital planning software. Experience of the observer had no influence on results. Furthermore, a high interrater reliability and correlation of digital planning specific parameters was found. Surgeons need to master limb geometry measurements and osteotomy planning on digital radiographs as digital planning reports are used for intercolleagual correspondence, teaching purposes and as medicolegal documents. The digital planning software tested agrees with the actual demands and could be recommended for deformity analysis and planning of osteotomies. Diagnostic studies, Level I.Keywords
This publication has 20 references indexed in Scilit:
- Prospective Outcomes of Young and Middle-Aged Adults With Medial Compartment Osteoarthritis Treated With a Proximal Tibial Opening Wedge OsteotomyArthroscopy: The Journal of Arthroscopic & Related Surgery, 2012
- High Complication Rate After Biplanar Open Wedge High Tibial Osteotomy Stabilized With a New Spacer Plate (Position HTO Plate) Without Bone SubstituteArthroscopy: The Journal of Arthroscopic & Related Surgery, 2011
- Reliability of lower extremity alignment measurement using radiographs and PACSKnee Surgery, Sports Traumatology, Arthroscopy, 2011
- Open-Wedge Osteotomy Using an Internal Plate Fixator in Patients With Medial-Compartment Gonarthritis and Varus Malalignment: 3-Year Results With Regard to Preoperative Arthroscopic and Radiographic FindingsArthroscopy: The Journal of Arthroscopic & Related Surgery, 2010
- Opening-wedge high tibial osteotomy without bone graftKnee Surgery, Sports Traumatology, Arthroscopy, 2010
- A mid term comparison of open wedge high tibial osteotomy vs unicompartmental knee arthroplasty for medial compartment osteoarthritis of the kneeJournal of Orthopaedic Surgery and Research, 2010
- Accuracy of high tibial osteotomy: comparison between open- and closed-wedge techniqueKnee Surgery, Sports Traumatology, Arthroscopy, 2009
- Reliability of lower limb alignment measures using an established landmark-based method with a customized computer software programRheumatology International, 2009
- The Role of Navigation in High Tibial Osteotomy: A Study of 50 PatientsOrthopedics, 2009
- Computer-assisted analysis of lower limb geometry: higher intraobserver reliability compared to conventional methodComputer Aided Surgery, 2006