AIM: To correlate dual-energy computed tomography (DECT) pulmonary angiography derived iodine maps with parameter maps of quantitative pulmonary perfusion magnetic resonance imaging (MRI). METHODS: Eighteen patients with pulmonary perfusion defects detected on DECT derived iodine maps were included in this prospective study and additionally underwent time-resolved contrast-enhanced pulmonary MRI [dynamic contrast enhanced (DCE)-MRI]. DCE-MRI data were quantitatively analyzed using a pixel-by-pixel deconvolution analysis calculating regional pulmonary blood flow (PBF), pulmonary blood volume (PBV) and mean transit time (MTT) in visually normal lung parenchyma and perfusion defects. Perfusion parameters were correlated to mean attenuation values of normal lung and perfusion defects on DECT iodine maps. Two readers rated the concordance of perfusion defects in a visual analysis using a 5-point Likert-scale (1 = no correlation, 5 = excellent correlation). RESULTS: In visually normal pulmonary tissue mean DECT and MRI values were: 22.6 ± 8.3 Hounsfield units (HU); PBF: 58.8 ± 36.0 mL/100 mL per minute; PBV: 16.6 ± 8.5 mL; MTT: 17.1 ± 10.3 s. In areas with restricted perfusion mean DECT and MRI values were: 4.0 ± 3.9 HU; PBF: 10.3 ± 5.5 mL/100 mL per minute, PBV: 5 ± 4 mL, MTT: 21.6 ± 14.0 s. The differences between visually normal parenchyma and areas of restricted perfusion were statistically significant for PBF, PBV and DECT (P < 0.0001). No linear correlation was found between MRI perfusion parameters and attenuation values of DECT iodine maps (PBF: r = 0.35, P = 0.15; PBV: r = 0.34, P = 0.16; MTT: r = 0.41, P = 0.08). Visual analysis revealed a moderate correlation between perfusion defects on DECT iodine maps and the parameter maps of DCE-MRI (mean score 3.6, κ 0.45). CONCLUSION: There is a moderate visual but not statistically significant correlation between DECT iodine maps and perfusion parameter maps of DCE-MRIKeywords
This publication has 26 references indexed in Scilit:
- Dual-Energy CT Pulmonary Angiography: A New Horizon in the Imaging of Acute Pulmonary ThromboembolismAmerican Journal of Roentgenology, 2009
- Lung Perfusion with Dual-energy Multidetector-row CT (MDCT): Feasibility for the Evaluation of Acute Pulmonary Embolism in 117 Consecutive PatientsAcademic Radiology, 2008
- Dual energy CT for the assessment of lung perfusion—Correlation to scintigraphyEuropean Journal of Radiology, 2008
- Dual-Energy CT Angiography of the Lung in Patients with Suspected Pulmonary Embolism: Initial ResultsRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2008
- Deconvolution of bolus-tracking data: a comparison of discretization methodsPhysics in Medicine & Biology, 2007
- New method for 3D parametric visualization of contrast-enhanced pulmonary perfusion MRI dataEuropean Radiology, 2007
- 3.0 Tesla High Spatial Resolution Contrast-Enhanced Magnetic Resonance Angiography (CE-MRA) of the Pulmonary CirculationInvestigative Radiology, 2007
- Material differentiation by dual energy CT: initial experienceEuropean Radiology, 2006
- First performance evaluation of a dual-source CT (DSCT) systemEuropean Radiology, 2005
- High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysisMagnetic Resonance in Medicine, 1996