Impact of Three Biological Decontamination Methods on Filtering Facepiece Respirator Fit, Odor, Comfort, and Donning Ease
- 11 June 2011
- journal article
- research article
- Published by Informa UK Limited in Journal of Occupational and Environmental Hygiene
- Vol. 8 (7), 426-436
- https://doi.org/10.1080/15459624.2011.585927
Abstract
The objective of this study was to determine if ultraviolet germicidal irradiation (UVGI), moist heat incubation (MHI), or microwave-generated steam (MGS) decontamination affects the fitting characteristics, odor, comfort, or donning ease of six N95 filtering facepiece respirator (FFR) models. For each model, 10 experienced test subjects qualified for the study by passing a standard OSHA quantitative fit test. Once qualified, each subject performed a series of fit tests to assess respirator fit and completed surveys to evaluate odor, comfort, and donning ease with FFRs that were not decontaminated (controls) and with FFRs of the same model that had been decontaminated. Respirator fit was quantitatively measured using a multidonning protocol with the TSI PORTACOUNT Plus and the N95 Companion accessory (designed to count only particles resulting from face to face-seal leakage). Participants' subjective appraisals of the respirator's odor, comfort, and donning ease were captured using a visual analog scale survey. Wilcoxon signed rank tests compared median values for fit, odor, comfort, and donning ease for each FFR and decontamination method against their respective controls for a given model. Two of the six FFRs demonstrated a statistically significant reduction (p < 0.05) in fit after MHI decontamination. However, for these two FFR models, post-decontamination mean fit factors were still ≥ 100. One of the other FFRs demonstrated a relatively small though statistically significant increase (p < 0.05) in median odor response after MHI decontamination. These data suggest that FFR users with characteristics similar to those in this study population would be unlikely to experience a clinically meaningful reduction in fit, increase in odor, increase in discomfort, or increased difficulty in donning with the six FFRs included in this study after UVGI, MHI, or MGS decontamination. Further research is needed before decontamination of N95 FFRs for purposes of reuse can be recommended.Keywords
This publication has 15 references indexed in Scilit:
- A method to determine the available UV-C dose for the decontamination of filtering facepiece respiratorsJournal of Applied Microbiology, 2010
- Analysis of Residual Chemicals on Filtering Facepiece Respirators After DecontaminationJournal of Occupational and Environmental Hygiene, 2010
- Development of a Test System To Evaluate Procedures for Decontamination of Respirators Containing Viral DropletsApplied and Environmental Microbiology, 2009
- Evaluation of Five Decontamination Methods for Filtering Facepiece RespiratorsAnnals of Occupational Hygiene, 2009
- Development of a Test System To Apply Virus-Containing Particles to Filtering Facepiece Respirators for the Evaluation of Decontamination ProceduresApplied and Environmental Microbiology, 2009
- Reducing Respirator Fit Test Errors: A Multi-Donning ApproachJournal of Occupational and Environmental Hygiene, 2005
- Effects of chemical and biological warfare remediation agents on the materials of museum objectsApplied Physics A, 2004
- Does UV irradiation affect polymer properties relevant to tissue engineering?Surface Science, 2001
- A Modified Protocol for Quantitative Fit Testing Using the PortaCount ®Applied Occupational and Environmental Hygiene, 2001
- Variation in Quantitative Respirator Fit Factors Due to Fluctuations in Leak Size During Fit TestingAihaj Journal, 1994