Analysis of Residual Chemicals on Filtering Facepiece Respirators After Decontamination
- 3 June 2010
- journal article
- research article
- Published by Taylor & Francis Ltd in Journal of Occupational and Environmental Hygiene
- Vol. 7 (8), 437-445
- https://doi.org/10.1080/15459624.2010.484794
Abstract
The N95 filtering facepiece respirator (FFR) is commonly used to protect individuals from infectious aerosols. Health care experts predict a shortage of N95 FFRs if a severe pandemic occurs, and an option that has been suggested for mitigating such an FFR shortage is to decontaminate and reuse the devices. Before the effectiveness of this strategy can be established, many parameters affecting respiratory protection must be measured: biocidal efficacy of the decontamination treatment, filtration performance, pressure drop, fit, and toxicity to the end user post treatment. This research effort measured the amount of residual chemicals created or deposited on six models of FFRs following treatment by each of 7 simple decontamination technologies. Measured amounts of decontaminants retained by the FFRs treated with chemical disinfectants were small enough that exposure to wearers will be below the permissible exposure limit (PEL). Toxic by-products were also evaluated, and two suspected toxins were detected after ethylene oxide treatment of FFR rubber straps. The results provide encouragement to efforts promoting the evolution of effective strategies for decontamination and reuse of FFRs.Keywords
This publication has 19 references indexed in Scilit:
- Emergence of a Novel Swine-Origin Influenza A (H1N1) Virus in HumansThe New England Journal of Medicine, 2009
- Measurement of Airborne Influenza Virus in a Hospital Emergency DepartmentClinical Infectious Diseases, 2009
- Inactivation of influenza A viruses in the environment and modes of transmission: A critical reviewJournal of Infection, 2008
- N95 and P100 Respirator Filter Efficiency Under High Constant and Cyclic FlowJournal of Occupational and Environmental Hygiene, 2008
- Do N95 respirators provide 95% protection level against airborne viruses, and how adequate are surgical masks?American Journal of Infection Control, 2006
- Review of Aerosol Transmission of Influenza A VirusEmerging Infectious Diseases, 2006
- Novel refreshableN‐halamine polymeric biocides: Grafting hydantoin‐containing monomers onto high performance fibers by a continuous processJournal of Applied Polymer Science, 2003
- Performance of N95 Respirators: Filtration Efficiency for Airborne Microbial and Inert ParticlesAihaj Journal, 1998
- Collection of three bacterial aerosols by respirator and surgical mask filters under varying conditions of flow and relative humidityAnnals of Occupational Hygiene, 1997
- COLLECTION OF THREE BACTERIAL AEROSOLS BY RESPIRATOR AND SURGICAL MASK FILTERS UNDER VARYING CONDITIONS OF FLOW AND RELATIVE HUMIDITYAnnals of Work Exposures and Health, 1997