Continuous Glucose Monitoring, Future Products, and Update on Worldwide Artificial Pancreas Projects
- 1 February 2016
- journal article
- review article
- Published by Mary Ann Liebert Inc in Diabetes Technology & Therapeutics
- Vol. 18 (S2), S2-53
- https://doi.org/10.1089/dia.2015.0345
Abstract
The development of accurate and easy-to-use continuous glucose monitoring (CGM) improved diabetes treatment by providing additional temporal information on glycemia and glucose trends to patient and physician. Although CGM enables users to lower their average glucose level without an increased incidence of hypoglycemia, this comes at the price of additional patient effort. Automation of insulin administration, also known as closed-loop (CL) or artificial pancreas treatment, has the promise to reduce patient effort and improve glycemic control. CGM data serve as the conditional input for insulin automation devices. The first commercial product for partial automation of insulin administration used insulin delivery shutoff at a predefined glucose level. These systems showed a reduction in hypoglycemia. Insulin-only CL devices show increased time spent in euglycemia and a reduction of hypo- and hyperglycemia. Improved glycemic control, coinciding with a minor decrease in hemoglobin A1c level, was confirmed in recent long-term home studies investigating these devices, paving the way for pivotal studies for commercialization of the artificial pancreas. Although the first results from dual-hormone CL systems are promising, because of increased cost of consumables of these systems, long-term head-to-head studies will have to prove superiority over insulin-only approaches. Now CL glucose control for daily use might finally become reality. Improved continuous glucose sensing technology, miniaturization of electrical devices, and development of algorithms were key in making this possible. Clinical adoption challenges, including device usability and reimbursement, need to be addressed. Time will tell for which patient groups CL systems will be reimbursed and whether these devices can deliver the promise that they hold.Keywords
This publication has 49 references indexed in Scilit:
- Threshold-Based Insulin-Pump Interruption for Reduction of HypoglycemiaThe New England Journal of Medicine, 2013
- Real-Time Improvement of Continuous Glucose Monitoring AccuracyDiabetes Care, 2013
- Effect of Pramlintide on Prandial Glycemic Excursions During Closed-Loop Control in Adolescents and Young Adults With Type 1 DiabetesDiabetes Care, 2012
- The Landmark JDRF Continuous Glucose Monitoring Randomized Trials: a Look Back at the Accumulated EvidenceJournal of Cardiovascular Translational Research, 2012
- Continuous glucose monitoring systems for type 1 diabetes mellitusEmergencias, 2012
- Sensor-augmented pump therapy lowers HbA1c in suboptimally controlled Type 1 diabetes; a randomized controlled trialDiabetic Medicine, 2011
- Glycaemic control in type 1 diabetes during real time continuous glucose monitoring compared with self monitoring of blood glucose: meta-analysis of randomised controlled trials using individual patient dataBMJ, 2011
- Novel Use of Glucagon in a Closed-Loop System for Prevention of Hypoglycemia in Type 1 DiabetesDiabetes Care, 2010
- Epidemiology of severe hypoglycemia in the diabetes control and complications trialAmerican Journal Of Medicine, 1991
- Normalization of Glycemia in Diabetics During Meals with Insulin and Glucagon Delivery by the Artificial PancreasDiabetes, 1977