Abstract
Accelerated degenerative changes at intervertebral levels adjacent to a spinal fusion, the so-called adjacent segment degeneration (ASD), have been reported in many clinical studies. Even though the pathogenesis of ASD is still widely unknown, biomechanical in vitro approaches have often been used to investigate the impact of spinal instrumentation on the adjacent segments. The goal of this review is (1) to summarize the results of these studies with respect to the applied protocol and loads and (2) to discuss if the assumptions made for the different protocols match the patients’ postoperative situation. A systematic MEDLINE search was performed using the keywords “adjacent”, “in vitro” and “spine” in combination. This revealed a total of 247 articles of which 33 met the inclusion criteria. In addition, a mechanical model was developed to evaluate the effects of the current in vitro biomechanical test protocols on the changes in the adjacent segments resulting from different stiffnesses of the “treated” segment. The surgical treatments reported in biomechanical in vitro studies investigating ASD can be categorized into fusion procedures, total disc replacement (TDR), and dynamic implants. Three different test protocols (i.e. flexibility, stiffness, hybrid) with different loading scenarios (e.g. pure moment or eccentric load) are used in current biomechanical in vitro studies investigating ASD. According to the findings with the mechanical model, we found that the results for fusion procedures highly depend on the test protocol and method of load application, whereas for TDR and dynamic implants, most studies did not find significant changes in the adjacent segments, independent of which test protocol was used. The three test protocols mainly differ in the assumption on the postoperative motion behavior of the patients, which is the main reason for the conflicting findings. However, the protocols have never been validated using in vivo kinematic data. In a parallel review on in vivo kinematics by Malakoutian et al., it was found that the assumption that the patients move exactly the same after fusion implemented with the stiffness- and hybrid protocol does not match the patients’ behavior. They showed that the motion of the whole lumbar spine rather tends to decrease in most studies, which could be predicted by the flexibility protocol. However, when the flexibility protocol is used with the “gold standard” pure moment, the difference in the kinematic changes between the cranial and caudal adjacent segment cannot be reproduced, putting the validity of current in vitro protocols into question.Keywords
This publication has 54 references indexed in Scilit:
- Preliminary Investigations on Intradiscal Pressures during Daily Activities: An In Vivo Study Using the Merino SheepPLOS ONE, 2013
- Adjacent Level Disk Disease—Is it Really a Fusion Disease?Orthopedic Clinics of North America, 2011
- Biomechanical evaluation of posterior lumbar dynamic stabilization: an in vitro comparison between Universal Clamp and Wallis systemsEuropean Spine Journal, 2010
- Dynamic stabilization adjacent to single-level fusion: Part I. Biomechanical effects on lumbar spinal motionEuropean Spine Journal, 2010
- Biomechanical Study of Lumbar Spinal Arthroplasty with a Semi-Constrained Artificial Disc (Activ L) in the Human Cadaveric SpineJournal of Korean Neurosurgical Society, 2009
- Immediate Biomechanical Effects of Lumbar Posterior Dynamic Stabilization Above a Circumferential FusionSpine, 2007
- StabilimaxNZ® versus simulated fusion: evaluation of adjacent-level effectsEuropean Spine Journal, 2007
- Are animal models useful for studying human disc disorders/degeneration?European Spine Journal, 2007
- Hybrid multidirectional test method to evaluate spinal adjacent-level effectsClinical Biomechanics, 2007
- Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implantsEuropean Spine Journal, 1998