An Experimental Study on the Lateral Impact of Fully Clamped Mild Steel Pipes

Abstract
This report presents some experimental data that were recorded from 130 impact tests on mild steel pipes in two drop hammer rigs. The pipes were fully clamped across a span which was ten times the corresponding outside pipe diameters which lie between 22 and 324 mm. All of the pipes except five had wall thicknesses of 2 mm approximately and were impacted laterally by a rigid wedge indenter at the mid span, one-quarter span or near to a support. The impact velocities ranged up to 14 m/s and caused various failure modes. Some comparisons between two sets of experimental results indicate that the laws of geometrically similar scaling are almost satisfied over a scale range of approximately five.