Surface Acoustic Wave Nebulization of Peptides As a Microfluidic Interface for Mass Spectrometry
- 5 April 2010
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 82 (10), 3985-3989
- https://doi.org/10.1021/ac100372c
Abstract
We describe the fabrication of a surface acoustic wave (SAW) device on a LiNbO3 piezoelectric transducer for the transfer of nonvolatile analytes to the gas phase at atmospheric pressure (a process referred to as nebulization or atomization). We subsequently show how such a device can be used in the field of mass spectrometry (MS) detection, demonstrating that SAW nebulization (SAWN) can be performed either in a discontinuous or pulsed mode, similar to that for matrix assisted laser desorption ionization (MALDI) or in a continuous mode like electrospray ionization (ESI). We present data showing the transfer of peptides to the gas phase, where ions are detected by MS. These peptide ions were subsequently fragmented by collision-induced dissociation, from which the sequence was assigned. Unlike MALDI mass spectra, which are typically contaminated with matrix ions at low m/z, the SAWN generated spectra had no such interference. In continuous mode, the SAWN plume was sampled on a microsecond time scale by a linear ion trap mass spectrometer and produced multiply charged peptide precursor ions with a charge state distribution shifted to higher m/z compared to an identical sample analyzed by ESI. The SAWN technology also provides the opportunity to re-examine a sample from a flat surface, repeatedly. The process can be performed without the need for capillaries, which can clog, reservoirs, which dilute the sample, and electrodes, which when in direct contact with sample, cause unwanted electrochemical oxidation. In both continuous and pulsed sampling modes, the quality of precursor ion scans and tandem mass spectra of peptides was consistent across the plume’s lifetime.Keywords
This publication has 29 references indexed in Scilit:
- The extraction of liquid, protein molecules and yeast cells from paper through surface acoustic wave atomizationLab on a Chip, 2009
- Rapid fluid flow and mixing induced in microchannels using surface acoustic wavesEurophysics Letters, 2009
- Protein Oxidative Modifications During Electrospray Ionization: Solution Phase Electrochemistry or Corona Discharge-Induced Radical Attack?Analytical Chemistry, 2009
- On-chip technologies for multidimensional separationsLab on a Chip, 2009
- Rapid generation of protein aerosols and nanoparticles via surface acoustic wave atomizationNanotechnology, 2008
- On the Benefits of Acquiring Peptide Fragment Ions at High Measured Mass AccuracyJournal of the American Society for Mass Spectrometry, 2008
- Evaporative self-assembly assisted synthesis of polymeric nanoparticles by surface acoustic wave atomizationNanotechnology, 2008
- Active micro-mixers using surface acoustic waves on Y-cut 128° LiNbO3Journal of Micromechanics and Microengineering, 2006
- A device for fabricating protein chips by using a surface acoustic wave atomizer and electrostatic depositionSensors and Actuators B: Chemical, 2005
- Development of Novel Atomization System Based on SAW StreamingJapanese Journal of Applied Physics, 2004