Abstract
A dual navigator‐gated, flow‐sensitive alternating inversion recovery (FAIR) true fast imaging with steady precession (True‐FISP) sequence has been developed for accurate quantification of renal perfusion. FAIR methods typically overestimate renal perfusion when respiratory motion causes the inversion slice to move away from the imaging slice, which then incorporates unlabeled spins from static tissue. To overcome this issue, the dual navigator scheme was introduced to track inversion and imaging slices, and thus to ensure the same position for both slices. Accuracy was further improved by a well‐defined bolus length, which was achieved by a modification version of Q2TIPS (quantitative imaging of perfusion using a single subtraction, second version with interleaved thin‐slice TI1 periodic saturation): a series of saturation pulses was applied to both sides of the imaging slice at a certain time after the inversion. The dual navigator‐gated technique was tested in eight volunteers. The measured renal cortex perfusion rates were between 191 and 378 mL/100 g/min in the renal cortex with a mean of 376 mL/100 g/min. The proposed technique may prove most beneficial for noncontrast‐based renal perfusion quantification in young children and patients who may have difficulty holding their breath for prolonged periods or are sedated/anesthetized. Magn Reson Med, 2010.Keywords
Funding Information
- NHLBI (2U54HL070590-06)
- American Lebanese Syrian Associated Charities
This publication has 28 references indexed in Scilit:
- Mechanism of NSF: New evidence challenging the prevailing theoryJournal of Magnetic Resonance Imaging, 2009
- Strategies for reducing respiratory motion artifacts in renal perfusion imaging with arterial spin labelingMagnetic Resonance in Medicine, 2009
- Empirical optimization of ASL data analysis using an ASL data processing toolbox: ASLtbxMagnetic Resonance Imaging, 2008
- Slice profile optimization in arterial spin labeling using presaturation and optimized RF pulsesMagnetic Resonance Imaging, 2006
- Human cardiac imaging at 3 T using phased array coilsMagnetic Resonance in Medicine, 2000
- Quantitation of renal perfusion using arterial spin labeling with FAIR-UFLAREMagnetic Resonance Imaging, 2000
- Implementation and evaluation of frequency offset corrected inversion (FOCI) pulses on a clinical MR systemMagnetic Resonance in Medicine, 1997
- Quantification of relative cerebral blood flow change by flow‐sensitive alternating inversion recovery (FAIR) technique: Application to functional mappingMagnetic Resonance in Medicine, 1995
- Renal perfusion in humans: MR imaging with spin tagging of arterial water.Radiology, 1995
- Water Content and NMR Relaxation Time Gradients in the Rabbit KidneyInvestigative Radiology, 1986