Objectives The purposes of this study were to investigate interobserver reproducibility using acoustic radiation force impulse imaging and to develop an acoustic radiation force impulse scoring system. Methods Fifty healthy volunteers with normal liver function test values were selected for the study. Shear wave velocity measurements, expressed in meters per second, were taken in a deep portion of liver segment 6. Two observers with different levels of experience performed the measurements independently and blindly. Results All of the measurements taken by the 2 observers were valid, even in volunteers with a body mass index of greater than 28 kg/m2. The results point to very good interobserver reproducibility of shear wave velocity measurements, with an intraclass coefficient correlation of 0.86 (P < .001). Conclusions The results of this study show that shear wave velocity measurements using the acoustic radiation force impulse technique and a standardized protocol are accurate and reproducible.Keywords
This publication has 14 references indexed in Scilit:
- Acoustic radiation force impulse: a new ultrasonographic technology for the widespread noninvasive diagnosis of liver fibrosisEuropean Journal of Gastroenterology & Hepatology, 2010
- Acoustic Radiation Force Impulse Elastography as Compared to Transient Elastography and Liver Biopsy in Patients with Chronic HepatopathiesUltraschall in der Medizin - European Journal of Ultrasound, 2010
- Comparison of acoustic radiation force impulse imaging (ARFI) to liver biopsy histologic scores in the evaluation of chronic liver disease: A pilot studyAnnals of Hepatology, 2010
- Tissue Quantification With Acoustic Radiation Force Impulse Imaging: Measurement Repeatability and Normal Values in the Healthy LiverAmerican Journal of Roentgenology, 2010
- Measurement of Liver Elasticity with Acoustic Radiation Force Impulse (ARFI) Technology: An Alternative Noninvasive Method for Staging Liver Fibrosis in Viral HepatitisUltraschall in der Medizin - European Journal of Ultrasound, 2010
- Evaluation of acoustic radiation force impulse elastography for fibrosis staging of chronic liver disease: a pilot studyLiver International, 2010
- Liver Fibrosis in Viral Hepatitis: Noninvasive Assessment with Acoustic Radiation Force Impulse Imaging versus Transient ElastographyRadiology, 2009
- Acoustic radiation force imaging sonoelastography fornoninvasive staging of liver fbrosisWorld Journal of Gastroenterology, 2009
- An Integrated Indenter-ARFI Imaging System for Tissue Stiffness QuantificationUltrasonic Imaging, 2008
- Prospective comparison of transient elastography, Fibrotest, APRI, and liver biopsy for the assessment of fibrosis in chronic hepatitis CGastroenterology, 2005