Effect of a plant-based hemostatic agent on microleakage of self-etching adhesives
Open Access
- 1 January 2013
- journal article
- Published by Medicina Oral, S.L. in Medicina Oral Patología Oral y Cirugia Bucal
- Vol. 18 (1), e124-e129
- https://doi.org/10.4317/medoral.17959
Abstract
Objective: This in vitro study evaluated the effect of Ankaferd Blood Stopper (ABS) contamination on the microleakage of one-step and two-step self-etching adhesives. Study design: Class V cavities were prepared at the cemento-enamel junction on both buccal and lingual surfaces of 60 freshly extracted human molars. Teeth were randomly assigned into three groups according to contamination material applied (Group I, no contamination; Group II, blood contamination; Group III, ABS contamination). In contaminated groups, one drop of blood and ABS solution was applied directly to the dentin surface and air-dried. Each group was further divided into two subgroups according to bonding agent used [Group A, Clearfil SE Bond (two-step self-etching adhesive); Group B, Adper Easy One (one-step self-etching adhesive)]. Adhesive materials were applied according to the manufacturers’ recommendations. The specimens were restored using a universal microhybrid composite (Arabesk). After thermocycling (5000x, 5°C – 55°C) and immersion in a 0.5% basic fuchsin, dye penetration was evaluated under a stereomicroscope. Statistical analysis was performed with Kruskal-Wallis and Mann-Whitney U tests at p < 0.05. Results: Significantly higher microleakage scores were observed when one-step self-etching adhesive was applied to blood- and ABS-contaminated dentin. However, when a two-step self etching adhesive was used, microleakage was observed only following blood contamination, not following ABS contamination. Conclusions: Although, blood contamination before adhesive application resulted in increased microleakage with both one-step and two-step self-etching adhesive systems, ABS contamination did not affect microleakage when a two-step self-ething adhesive system was used.Keywords
This publication has 29 references indexed in Scilit:
- Plant Extract Ankaferd Blood Stopper Effect on Bond StrengthAngle Orthodontist, 2010
- Effects of Blood Contamination on Microtensile Bond Strength to Dentin of Three Self-etch AdhesivesOperative Dentistry, 2010
- Marginal permeability of one step self-etch adhesives: Effects of double application or the application of hydrophobic layerJournal of Conservative Dentistry, 2010
- Microleakage in Resin Composite Restorations After Antimicrobial Pre-treatments: Effect of KTP Laser, Chlorhexidine Gluconate and Clearfil Protect BondOperative Dentistry, 2009
- Evaluation of a New Hemostatic Agent Ankaferd Blood Stopper in Experimental Liver LacerationJournal of Investigative Surgery, 2009
- Two-year clinical performance of two one-step self-etching adhesives in the restoration of cervical lesionsClinical Oral Investigations, 2008
- Comparison of Enamel and Dentin Microshear Bond Strengths of a Two-step Self-etching Priming System with Five All-in-One SystemsOperative Dentistry, 2008
- Dentine deproteinization and microleakage around gingival third resin restorationsJournal of Conservative Dentistry, 2008
- Effect of Blood Contamination with 1-step Self-etching Adhesives on Microtensile Bond Strength to DentinOperative Dentistry, 2006
- The effect of blood contamination on the shear bond strength of orthodontic brackets with the use of a new self-etch primerAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2003