SNR Dependence of Optimal Parameters for Apparent Diffusion Coefficient Measurements
- 7 October 2010
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 30 (2), 424-437
- https://doi.org/10.1109/tmi.2010.2084583
Abstract
Optimizing the diffusion-weighted imaging (DWI) parameters (i.e., the b-value and the number of image averages) to the tissue of interest is essential for producing high-quality apparent diffusion coefficient (ADC) maps. Previous investigation of this optimization was performed assuming Gaussian noise statistics for the ADC map, which is only valid for high signal-to-noise ratio (SNR) imaging. In this work, the true statistics of the noise in ADC maps are derived, followed by an optimization of the DWI parameters as a function of the imaging SNR. Specifically, it is demonstrated that the optimum b-value is a monotonically increasing function of the imaging SNR, which converges to the optimum b-value from previously proposed approaches for high-SNR cases, while exhibiting a significant deviation from this asymptote for low-SNR situations. Incorporating the effects of T2 weighting further increases the SNR dependence of the optimal parameters. The proposed optimization scheme is particularly important for high-resolution DWI, which intrinsically suffers from low SNR and therefore cannot afford the use of the conventional high b-values. Comparison scans were performed for high-resolution DWI of the spinal cord, demonstrating the improvements in the resulting images and the ADC maps achieved by this method.Keywords
This publication has 21 references indexed in Scilit:
- Maximum a posteriori estimation of diffusion tensor parameters using a Rician noise model: Why, how and butNeuroImage, 2008
- A general framework for experiment design in diffusion MRI and its application in measuring direct tissue‐microstructure featuresMagnetic Resonance in Medicine, 2008
- DWI of the spinal cord with reduced FOV single‐shot EPIMagnetic Resonance in Medicine, 2008
- Optimal estimation of the diffusion coefficient from non-averaged and averaged noisy magnitude dataJournal of Magnetic Resonance, 2007
- Diffusion Imaging of the Human Spinal Cord and the Vertebral ColumnTopics in Magnetic Resonance Imaging, 2003
- Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imagingMagnetic Resonance in Medicine, 1999
- In vivo measurement of T2 distributions and water contents in normal human brainMagnetic Resonance in Medicine, 1997
- Image reconstruction for echo planar imaging with nonequidistant k‐space samplingMagnetic Resonance in Medicine, 1992
- Notes on the use of propagation of error formulasJournal of Research of the National Bureau of Standards, Section C: Engineering and Instrumentation, 1966
- Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field GradientThe Journal of Chemical Physics, 1965