Assessment of the variability in the anatomical position and size of the subthalamic nucleus among patients with advanced Parkinson’s disease using magnetic resonance imaging
- 6 October 2009
- journal article
- Published by Springer Science and Business Media LLC in Acta Neurochirurgica
- Vol. 152 (2), 201-210
- https://doi.org/10.1007/s00701-009-0514-z
Abstract
Targeting of the subthalamic nucleus (STN) during deep brain stimulation (DBS) surgery using standard atlas coordinates is used in some centers. Such coordinates are accurate for only a subgroup of patients, and subgroup size depends on the extent of inter-individual variation in STN position/size and degree to which atlas represents average anatomical relations. Few studies have addressed this issue. Sixty-two axial T2-weighted magnetic resonance (MR) images of the brain (1.5 T) were obtained before STN-DBS in 62 patients (37 males) with Parkinson’s disease using a protocol optimized for STN visualization. Image distortion was within sub-millimeter range. Midcommissural point (MCP)-derived coordinates of STN borders, STN center, and other brain landmarks were obtained using stereotactic software. MR-derived measurements were compared to Schaltenbrand and Wahren Atlas. We evaluated 117 best-visualized STNs. STN dimensions and coordinates of its center were highly variable. STN lateral coordinate ranged 8.7 mm–14.5 mm from MCP, A-P coordinate 3.5 mm posterior to 0.5 mm anterior to MCP, and vertical coordinate 1.3 mm–6 mm below MCP. The antero-posterior nucleus dimension varied by 8 mm and lateral-medial dimension by 5.8 mm. Differences between mean values of MR-derived data sets and Atlas values were statistically significant but moderate, excluding AC-PC length, for which the Atlas value was below the 1st percentile of the MR data set. The STN lateral coordinate strongly correlated with the width of the third ventricle (r = 0.73, p < 0.001). It is now possible to directly evaluate STNs at 1.5 T with minimal image distortion, which reveals variation in STN position and dimensions in the range of nucleus size. This puts under question the rationale of use of standard STN coordinates during DBS surgery.Keywords
This publication has 23 references indexed in Scilit:
- Safety of Anterior Commissure-Posterior Commissure-Based Target Calculation of the Subthalamic Nucleus in Functional Stereotactic ProceduresStereotactic and Functional Neurosurgery, 2007
- Variability of the subthalamic nucleus: The case for direct MRI guided targetingBritish Journal of Neurosurgery, 2007
- Pretargeting For The Implantation Of Stimulation Electrodes Into The Subthalamic Nucleus:A Comparative Study Of Magnetic Resonance Imaging And VentriculographyOperative Neurosurgery, 2006
- Reliability of atlas-derived coordinates in deep brain stimulationActa Neurochirurgica, 2005
- Correspondence of microelectrode mapping with magnetic resonance imaging for subthalamic nucleus proceduresSurgical Neurology, 2005
- Determining the position and size of the subthalamic nucleus based on magnetic resonance imaging results in patients with advanced Parkinson diseaseJournal of Neurosurgery, 2004
- Magnetic Resonance Imaging-Based Morphometry and Landmark Correlation of Basal Ganglia NucleiActa Neurochirurgica, 2002
- A prospective comparison between three-dimensional magnetic resonance imaging and ventriculography for target-coordinate determination in frame-based functional stereotactic neurosurgeryJournal of Neurosurgery, 1999
- Placement of Deep Brain Stimulators into the Subthalamic Nucleus: Technical ApproachStereotactic and Functional Neurosurgery, 1999
- MRI Distortion and Stereotactic Neurosurgery Using the Cosman-Roberts-Wells and Leksell FramesStereotactic and Functional Neurosurgery, 1996