Automatic Tube Current Modulation and Tube Voltage Selection in Pediatric Computed Tomography
Open Access
- 1 May 2019
- journal article
- research article
- Published by Ovid Technologies (Wolters Kluwer Health) in Investigative Radiology
- Vol. 54 (5), 265-272
- https://doi.org/10.1097/rli.0000000000000537
Abstract
The aim of this study was to investigate the effects of a modern automatic tube current modulation (ATCM) and automatic tube voltage selection (ATVS) system on radiation dose and image quality in pediatric head, and torso computed tomography (CT) examinations for various clinical indications. Four physical anthropomorphic phantoms that represent the average individual as neonate, 1-year-old, 5-year-old, and 10-year-old child were used. Standard head, thorax, and abdomen/pelvis acquisitions were performed with (1) fixed tube current, (2) ATCM, and (3) ATVS. Acquisitions were performed at various radiation dose levels to generate images at different levels of quality. Reference volume CT dose index (CTDIvol), reference image noise, and reference contrast-to-noise ratios were determined. The potential dose reductions with ATCM and ATVS were assessed. The percent reduction of CTDIvol with ATCM ranged from 8% to 24% for head, 16% to 39% for thorax, and 25% to 41% for abdomen/pelvis. The percent reduction of CTDIvol with ATVS varied on the clinical indication. In CT angiography, ATVS resulted to the highest dose reduction, which was up to 70% for head, 77% for thorax, and 34% for abdomen/pelvis. In noncontrast examinations, ATVS increased dose by up to 21% for head, whereas reduced dose by up to 34% for thorax and 48% for abdomen/pelvis. In pediatric CT, the use of ATCM significantly reduces radiation dose and maintains image noise. The additional use of ATVS reduces further the radiation dose for thorax and abdomen/pelvis, and maintains contrast-to-noise ratio for the specified clinical diagnostic task.Keywords
This publication has 23 references indexed in Scilit:
- Comparison of Iodine Density Measurement Among Dual-Energy Computed Tomography Scanners From 3 VendorsInvestigative Radiology, 2018
- Iodine Concentration and Optimization in Computed Tomography AngiographyInvestigative Radiology, 2016
- Effect of X-ray Tube Parameters and Iodine Concentration on Image Quality and Radiation Dose in Cerebral Pediatric and Adult CT AngiographyInvestigative Radiology, 2013
- Optimal Tube Potential for Radiation Dose Reduction in Pediatric CT: Principles, Clinical Implementations, and PitfallsRadioGraphics, 2011
- Automatic selection of tube potential for radiation dose reduction in CT: A general strategyMedical Physics, 2009
- Pediatric Body MDCT: A 5-Year Follow-Up Survey of Scanning Parameters Used by Pediatric RadiologistsAmerican Journal of Roentgenology, 2008
- Hypervascular Liver Tumors: Low Tube Voltage, High Tube Current Multi–Detector Row CT for Enhanced Detection—Phantom StudyRadiology, 2008
- Radiation Dose Reduction without Degradation of Low-Contrast Detectability at Abdominal Multisection CT with a Low–Tube Voltage Technique: Phantom StudyRadiology, 2005
- Radiation Dose and Image Quality in Pediatric CT: Effect of Technical Factors and Phantom Size and ShapeRadiology, 2004
- Comparison of Z-Axis Automatic Tube Current Modulation Technique with Fixed Tube Current CT Scanning of Abdomen and PelvisRadiology, 2004