Automatic selection of tube potential for radiation dose reduction in CT: A general strategy
- 10 December 2009
- journal article
- radiation imaging-physics
- Published by Wiley in Medical Physics
- Vol. 37 (1), 234-243
- https://doi.org/10.1118/1.3264614
Abstract
Purpose To optimize radiation dose efficiency in CT while maintaining image quality, it is important to select the optimal tube potential. The selection of optimal tube potential, however, is highly dependent on patient size and diagnostic task. The purpose of this work was to develop a general strategy that allows for automatic tube potential selection for each individual patient and each diagnostic task. Methods The authors propose a general strategy that allows automatic adaptation of the tube potential as a function of patient size and diagnostic task, using a novel index of image quality, “iodine contrast to noise ratio with a noise constraint (iCNR_NC),” to characterize the different image quality requirements by various clinical applications. The relative dose factor (RDF) at each tube potential to achieve a target image quality was then determined as a function of patient size and the noise constraint parameter. A workflow was developed to automatically identify the optimal tube potential that is both dose efficient and practically feasible, incorporating patient size and diagnostic task. An experimental study using a series of semianthropomorphic thoracic phantoms was used to demonstrate how the proposed general strategy can be implemented and how the radiation dose reduction achievable by the tube potential selection depends on phantom sizes and noise constraint parameters. Results The proposed strategy provides a flexible and quantitative way to select the optimal tube potential based on the patient size and diagnostic task. The noise constraint parameter can be adapted for different clinical applications. For example, for noncontrast routine exams; for contrast‐enhanced routine exams; and for CT angiography. For the five thoracic phantoms in the experiment, when , the optimal tube potentials were 80, 100, 100, 120, 120, respectively. The corresponding RDFs (relative to 120 kV) were 78.0%, 90.9%, 95.2%, 100%, and 100%. When , the optimal tube potentials were 80, 80, 80, 100, 100, respectively, with corresponding RDFs of 34.7%, 44.7%, 54.7%, 60.8%, and 89.5%. Conclusions A general strategy to automatically select the most dose efficient tube potential for CT exams was developed that takes into account patient size and diagnostic task. Dependent on the patient size and the selection of noise constraint parameter for different diagnostic tasks, the dose reduction at each tube potential, quantified explicitly with the RDF, varies significantly.Keywords
Funding Information
- Department of Radiology, Mayo Clinic Rochester
This publication has 29 references indexed in Scilit:
- CT DOSE: HOW TO MEASURE, HOW TO REDUCEHealth Physics, 2008
- Computed Tomography — An Increasing Source of Radiation ExposureThe New England Journal of Medicine, 2007
- Radiation Risk to Children From Computed TomographyPEDIATRICS, 2007
- Review of radiation risks from computed tomography: essentials for the pediatric surgeonJournal of Pediatric Surgery, 2007
- Contrast-medium-induced nephropathy correlated to the ratio between dose in gram iodine and estimated gfr in ml/minActa Radiologica, 2005
- Patient size and x-ray technique factors in head computed tomography examinations. II. Image qualityMedical Physics, 2004
- Patient size and x-ray technique factors in head computed tomography examinations. I. Radiation dosesMedical Physics, 2004
- Strategies of dose reductionPediatric Radiology, 2002
- In x-ray computed tomography, technique factors should be selected appropriate to patient sizeMedical Physics, 2001
- Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CTAmerican Journal of Roentgenology, 2001