A force‐measuring device combined with ultrasound‐based elastography for assessment of the uterine cervix
Open Access
- 20 January 2022
- journal article
- research article
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 101 (2), 241-247
- https://doi.org/10.1111/aogs.14309
Abstract
Introduction In this feasibility study, we hypothesize that the evaluation of cervical biomechanical strength can be improved if cervical length measurement is supplemented with quantitative elastography, which is a technique based on conventional ultrasound elastography combined with a force-measuring device. Our aims were to: (a) develop a force-measuring device; (b) introduce a cervical elastography index (CEI) and a cervical strength index (CSI; defined as cervical length × CEI); (c) evaluate how these indexes assess the cervical softening that takes place during normal pregnancy; and (d) how these indexes predict the cervical dilatation time from 4 to 10 cm. Material and methods An electronic force-measuring device was mounted on the handle of the transvaginal probe, allowing for force measurement when conducting elastography. The study group concerned with normal cervical softening included 44 unselected pregnant women. Outcomes were CEI and CSI at different gestational ages. The study group for labor induction included 26 singleton term pregnant women admitted for labor induction. Outcome was defined as cervical dilatation time from 4 to 10 cm. Elastography measured the changes in mean gray value (intensity) during manual compressions. Region of interest was set within the anterior cervical lip. Results We found that the mean of all variables regarding cervical softening decreased from early to late pregnancy: ie cervical length from 34 to 29 mm, CEI from 0.17 to 0.11 N, and CSI from 5.9 to 3.1 N mm. Moreover, the cervical dilatation time during labor induction was associated with CEI, although not statistically significantly (area under the ROC curve of 0.67), but not with the Bishop score, the cervical length, or the CSI. Conclusions We propose that quantitative elastography based on changes in the intensity of the B-mode ultrasound recording, in combination with a force-measuring device on the handle of the vaginal probe, deserves further investigation as an approach for evaluation of cervical biomechanical strength.Keywords
Funding Information
- Aase og Ejnar Danielsens Fond (20‐10‐0064)
This publication has 29 references indexed in Scilit:
- The rate of cervical change and the phenotype of spontaneous preterm birthAmerican Journal of Obstetrics and Gynecology, 2011
- Reference range for cervical length throughout pregnancy: non‐parametric LMS‐based model applied to a large sampleUltrasound in Obstetrics & Gynecology, 2009
- Research electronic data capture (REDCap)—A metadata-driven methodology and workflow process for providing translational research informatics supportJournal of Biomedical Informatics, 2008
- Cervical length and obstetric history predict spontaneous preterm birth: development and validation of a model to provide individualized risk assessmentUltrasound in Obstetrics & Gynecology, 2008
- Dynamics of Cervical Remodeling during Pregnancy and Parturition: Mechanisms and Current ConceptsSeminars in Reproductive Medicine, 2007
- Cervical length at 18–22 weeks of gestation for prediction of spontaneous preterm delivery in Hong Kong Chinese womenUltrasound in Obstetrics & Gynecology, 2005
- Sonographic measurement of cervical length in threatened preterm labor in singleton pregnancies with intact membranesUltrasound in Obstetrics & Gynecology, 2005
- Cervical length at 11–14 weeks' and 22–24 weeks' gestation evaluated by transvaginal sonography, and gestational age at deliveryUltrasound in Obstetrics & Gynecology, 2003
- Sonographic measurement of uterine cervix at 18–22 weeks' gestation and the risk of preterm deliveryObstetrics & Gynecology, 1998
- Practical Physics and Electronics of UltrasoundInternational Ophthalmology Clinics, 1979