Reference range for cervical length throughout pregnancy: non‐parametric LMS‐based model applied to a large sample
- 10 March 2009
- journal article
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 33 (4), 459-464
- https://doi.org/10.1002/uog.6332
Abstract
Objective Short cervical length is an important risk factor for preterm delivery. However, because cervical length changes throughout pregnancy, adequate risk estimation needs to take into account the gestational age (GA) at which the measurement is taken. We aimed to model cervical changes throughout pregnancy in order to be able to use Z‐scores, avoiding the confounding effect of GA. Methods Cervical length was prospectively measured in singleton pregnancies, as part of routine antenatal care over a 3‐year period. Measurements were taken at GA ranging from 16 to 36 weeks and only one measurement per pregnancy was used in the analysis. Because cervical length measurements are not normally distributed, we used a non‐parametric approach (LMS method) to best describe the distribution of the measurements with gestation. Results We included 6614 cervical length measurements. The LMS method identified changes in cervical length measurement across GA. We computed new reference charts and provide L, M and S values that allow the calculation of Z‐score at any GA from any cervical length measurement ‘Y’ using the formula: Z‐score = ((Y/M)L − 1)/(L × S). Conclusion Cervical length measurements do not have a normal distribution at a given GA and so require a statistical model that takes this into account. The model that we developed allows easy Z‐score calculation, therefore avoiding the confounding effect of GA and allowing straightforward monitoring of cervical length. Copyright © 2009 ISUOG. Published by John Wiley & Sons, Ltd.This publication has 30 references indexed in Scilit:
- CUSUM: a tool for ongoing assessment of performanceUltrasound in Obstetrics & Gynecology, 2008
- Statistical methods for constructing gestational age‐related reference intervals and centile charts for fetal sizeUltrasound in Obstetrics & Gynecology, 2007
- Analysis of Z‐score distribution for the quality control of fetal ultrasound measurements at 20–24 weeksUltrasound in Obstetrics & Gynecology, 2005
- Sonographic measurement of uterine cervix at 18–22 weeks' gestation and the risk of preterm deliveryObstetrics & Gynecology, 1998
- A Comparison of Statistical Methods for Age-related Reference IntervalsJournal of the Royal Statistical Society Series A: Statistics in Society, 1997
- Transvaginal ultrasonographic cervical assessment for the prediction of preterm deliveryThe Journal of Maternal-Fetal Medicine, 1996
- A longitudinal study of the cervix in pregnancy using transvaginal ultrasoundBJOG: An International Journal of Obstetrics and Gynaecology, 1996
- Early prediction of preterm delivery by transvaginal ultrasonographyUltrasound in Obstetrics & Gynecology, 1992
- Vaginosonographische Beobachtungen des zervikalen Verschlußapparates unter besonderer Berücksichtigung der ParitätGeburtshilfe und Frauenheilkunde, 1992
- Smoothing reference centile curves: The lms method and penalized likelihoodStatistics in Medicine, 1992