Ultrasound estimation of birth weight in twin pregnancy: comparison of biometry algorithms in the STORK multiple pregnancy cohort
Open Access
- 21 November 2013
- journal article
- research article
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 44 (2), 210-220
- https://doi.org/10.1002/uog.13253
Abstract
Objectives The aims of this study were first, to ascertain the accuracy of formulae for ultrasonographic birth-weight estimation in twin compared with singleton pregnancies and second, to assess the accuracy of sonographic examination in the prediction of birth-weight discordance in twin pregnancies. Methods This was a retrospective cohort study including both singleton and twin pregnancies. Routine biometry was recorded and estimated fetal weight (EFW) calculated using 33 different formulae. Only pregnancies that delivered within 48 h of the ultrasound scan were included (4280 singleton and 586 twin fetuses). Differences between the EFW and actual birth weight (ABW) were assessed by percentage error, accuracy in predictions within ± 10 % and ± 15% of error and use of the Bland–Altman method. The accuracy of prediction of the different cut-offs of birth-weight discordance in twin pregnancies was also assessed using the area under the receiver–operating characteristics curve (AUC). Results The overall mean absolute percentage error was ≤ 10 % for 25 formulae in singleton pregnancies compared with three formulae in twin pregnancies. The overall predictions within ± 10% and ± 15% of the ABW were 62.2% and 81.5% in singleton and 49.7% and 68.5% in twin pregnancies, respectively. When the formulae were categorized according to the biometric parameters included, those based on a combination of head, abdomen and femur measurements showed the lowest mean absolute percentage error, in both singleton and twin pregnancies. The predictive accuracy for 25% birth-weight discordance using the Hadlock 2 formula, as assessed by the AUC, was 0.87. Conclusions Ultrasound estimation of birth weight is less accurate in twin than in singleton pregnancies. Formulae that include a combination of head, abdomen and femur measurements perform best in both singleton and twin pregnancies. Copyright © 2013 ISUOG. Published by John Wiley & Sons LtdKeywords
This publication has 69 references indexed in Scilit:
- Prospective risk of late stillbirth in monochorionic twins: a regional cohort studyUltrasound in Obstetrics & Gynecology, 2012
- Systematic labeling of twin pregnancies on ultrasoundUltrasound in Obstetrics & Gynecology, 2011
- Validity of sonographic prediction of fetal weight and weight discordance in twin pregnanciesPrenatal Diagnosis, 2010
- New fetal weight estimation models using fractional limb volumeUltrasound in Obstetrics & Gynecology, 2009
- Intrauterine growth in multiple pregnancies in relation to fetal number, chorionicity and gestational ageUltrasound in Obstetrics & Gynecology, 2008
- Sonographic estimation of fetal weight: comparison of bias, precision and consistency using 12 different formulaeUltrasound in Obstetrics & Gynecology, 2007
- The effect of birth weight discordance on twin neonatal mortalityObstetrics & Gynecology, 2003
- Fetal weight estimation by three‐dimensional ultrasoundUltrasound in Obstetrics & Gynecology, 2000
- Sonographic measurement of the fetal femur: Factors affecting accuracyJournal of Clinical Ultrasound, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986