Frequency of bacterial contamination of platelet concentrates before and after introduction of diversion method in Japan
- 1 October 2009
- journal article
- Published by Wiley in Transfusion
- Vol. 49 (10), 2152-2157
- https://doi.org/10.1111/j.1537-2995.2009.02243.x
Abstract
BACKGROUND: Bacterial contamination of platelet concentrates (PCs) is the major infectious risk in transfusion medicine. To evaluate the necessity of implementing novel strategies for the reduction of bacterial contamination, it is necessary to establish a precise contamination frequency in PCs. STUDY DESIGN AND METHODS: The frequency of bacterial contamination in PCs issued by the Japanese Red Cross was determined using expired PCs before and after the implementation of the diversion method. The culture method was designed such that it yields the least possibility of false-negative results: platelet specimens were sampled after at least 4 days of storage and the inoculum volume was 10 mL for both aerobic and anaerobic bottle cultures. RESULTS: Of the 21,786 PCs cultured, 36 (0.17%) were confirmed to be bacterially contaminated before the implementation of the diversion method. After its implementation, the number of contaminated PCs decreased to 11 of 21,783 (0.05%) with a reduction rate of 71% and the number of contaminations of clinical importance was 4 (0.018%) excluding PCs positive for Propionibacterium acnes. The frequency of contamination by bacteria presumed to originate from donors' blood did not decrease. CONCLUSION: The effect of the diversion method on the frequency of bacterial contamination is robust. The low incidence of septic reactions after PC transfusion in Japan in spite of the contamination frequency being comparable to those in Western countries and the noninstitution of culture screening suggests the importance of a short shelf life (72 hr) for PCs introduced in Japan.Keywords
This publication has 24 references indexed in Scilit:
- Bacterial screening of apheresis platelets and the residual risk of septic transfusion reactions: the American Red Cross experience (2004‐2006)Transfusion, 2007
- Canadian experience with detection of bacterial contamination in apheresis plateletsTransfusion, 2007
- Two‐year experience with aerobic culturing of apheresis and whole blood–derived plateletsTransfusion, 2006
- Effects of skin disinfection method, deviation bag, and bacterial screening on clinical safety of platelet transfusions in the NetherlandsTransfusion, 2006
- Bacterial Detection of Platelets: Current Problems and Possible ResolutionsTransfusion Medicine Reviews, 2005
- Bacterial Contamination of Blood Components: Risks, Strategies, and RegulationHematology-American Society Hematology Education Program, 2003
- Evaluation of donor arm disinfection techniquesVox Sanguinis, 2001
- Efficacy of a new collection procedure for preventing bacterial contamination of whole‐blood donationsTransfusion, 2001
- Diversion of initial blood flow to prevent whole‐blood contamination by skin surface bacteria: an in vitro modelTransfusion, 2000
- Evaluation of donor skin disinfection methodsTransfusion, 1997