A Multistage Approach to Improve Performance of Computer-Aided Detection of Pulmonary Embolisms Depicted on CT Images: Preliminary Investigation
- 5 August 2010
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 58 (6), 1519-1527
- https://doi.org/10.1109/tbme.2010.2063702
Abstract
This study developed a computer-aided detection (CAD) scheme for pulmonary embolism (PE) detection and investigated several approaches to improve CAD performance. In the study, 20 computed tomography examinations with various lung diseases were selected, which include 44 verified PE lesions. The proposed CAD scheme consists of five basic steps: 1) lung segmentation; 2) PE candidate extraction using an intensity mask and tobogganing region growing; 3) PE candidate feature extraction; 4) false-positive (FP) reduction using an artificial neural network (ANN); and 5) a multifeature-based k-nearest neighbor for positive/negative classification. In this study, we also investigated the following additional methods to improve CAD performance: 1) grouping 2-D detected features into a single 3-D object; 2) selecting features with a genetic algorithm (GA); and 3) limiting the number of allowed suspicious lesions to be cued in one examination. The results showed that 1) CAD scheme using tobogganing, an ANN, and grouping method achieved the maximum detection sensitivity of 79.2%; 2) the maximum scoring method achieved the superior performance over other scoring fusion methods; 3) GA was able to delete “redundant” features and further improve CAD performance; and 4) limiting the maximum number of cued lesions in an examination reduced FP rate by 5.3 times. Combining these approaches, CAD scheme achieved 63.2% detection sensitivity with 18.4 FP lesions per examination. The study suggested that performance of CAD schemes for PE detection depends on many factors that include 1) optimizing the 2-D region grouping and scoring methods; 2) selecting the optimal feature set; and 3) limiting the number of allowed cueing lesions per examination.Keywords
This publication has 27 references indexed in Scilit:
- Pulmonary airways tree segmentation from CT examinations using adaptive volume of interestPublished by SPIE-Intl Soc Optical Eng ,2009
- Computer-Aided Diagnosis of Lung Cancer and Pulmonary Embolism in Computed Tomography—A ReviewAcademic Radiology, 2008
- Computer-aided Detection of Pulmonary Embolism on CT AngiographyJournal of Thoracic Imaging, 2007
- Computed tomography for pulmonary embolism diagnosis: the making of a reference standardJournal of Thrombosis and Haemostasis, 2005
- Pulmonary Nodules: Automated Detection on CT Images with Morphologic Matching Algorithm—Preliminary ResultsRadiology, 2005
- Vessel tree reconstruction in thoracic CT scans with application to nodule detectionIEEE Transactions on Medical Imaging, 2005
- Computerized detection of pulmonary embolism in spiral CT angiography based on volumetric image analysisIEEE Transactions on Medical Imaging, 2002
- Computer-Aided Detection in Mammography: An Assessment of Performance on Current and Prior ImagesAcademic Radiology, 2002
- Computed assisted detection of interval breast cancersEuropean Journal of Radiology, 2001
- 10.1162/153244303322753616Applied Physics Letters, 2000