Identification and quantification of fetal red blood cells in maternal blood by a dual‐color flow cytometric method: evaluation of the Fetal Cell Count kit
- 2 May 2007
- journal article
- Published by Wiley in Transfusion
- Vol. 47 (7), 1281-1289
- https://doi.org/10.1111/j.1537-2995.2007.01271.x
Abstract
As an alternative to the cumbersome Kleihauer-Betke test (KBT), flow cytometry represents a powerful method for the identification and quantification of fetal red blood cells (RBCs) in maternal circulation.The aim of this study was to evaluate the Fetal Cell Count kit (IQ Products), an innovative flow cytometric method, based on the combination of antibodies directed, respectively, against fetal hemoglobin (HbF) and carbonic anhydrase (CA), a marker expressed after birth, to discriminate fetal RBCs from adult F cells containing HbF. The investigation was performed by two French laboratories that compared the data obtained by flow cytometry and KBT in 455 pregnant or just-delivered women as well as in 124 artificial mixtures containing from 0.01 to 5.00 percent cord cells.The FL1/FL2 histogram allowed distinction between fetal RBCs (HbF+, CA-), F cells (HbF+, CA+), and adult RBCs (HbF-, CA+). The limits of detection and quantification were determined at 0.03 and 0.10 percent or 0.02 and 0.05 percent when analyzing 100,000 or 200,000 events, respectively. Linearity was demonstrated between 0.01 and 5.00 percent fetal cells in the mixtures (r = 0.95, p < 0.01). A good correlation between fluorescence-activated cell sorting (FACS) and KBT results was obtained with artificial mixtures (r = 0.94, p < 0.01). From the 405 Kleihauer-negative samples, none were identified as positive by FACS. Among the 50 Kleihauer-positive samples, 6 were shown not to contain fetal cells but F cells by FACS.With this new dual-color flow cytometric method, accurate evaluation of fetomaternal hemorrhage was achieved even in the face of HbF of maternal origin.This publication has 45 references indexed in Scilit:
- Quantification of fetomaternal hemorrhage: a comparative study of the manual and automated microscopic Kleihauer-Betke tests and flow cytometry in clinical samplesAmerican Journal of Obstetrics and Gynecology, 2004
- Fetal-Maternal Hemorrhage Detection in OntarioAmerican Journal of Clinical Pathology, 2003
- Multicenter clinical experience with flow cytometric method for fetomaternal hemorrhage detectionCytometry, 2002
- Semiautomated data analysis of flow cytometric estimation of fetomaternal hemorrhage in D− womenTransfusion, 2002
- Flow Cytometric Measurement of Hemoglobin F in RBCsAmerican Journal of Clinical Pathology, 2002
- A quality assurance scheme for the Kleihauer test: the Scottish experience 1988–1996Transfusion Medicine, 1997
- Measurement of feto-maternal haemorrhage: a comparative study of three Kleihauer techniques and two flow cytometry methodsClinical and Laboratory Haematology, 1997
- Use of a directly conjugated monoclonal anti‐D (BRAD‐3) for quantification of fetomaternal hemorrhage by flow cytometryTransfusion, 1996
- Expression of the human carbonic anhydrase I gene is activated late in fetal erythroid development and regulated by stage‐specific trans‐acting factorsBritish Journal of Haematology, 1990
- Fetomaternal hemorrhage: incidence, risk factors, time of occurrence, and clinical effectsTransfusion, 1990