Humidity control and hydrophilic glue coating applied to mounted protein crystals improves X-ray diffraction experiments
Open Access
- 17 August 2013
- journal article
- research article
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D-Structural Biology
- Vol. 69 (9), 1839-1849
- https://doi.org/10.1107/s0907444913018027
Abstract
Protein crystals are fragile, and it is sometimes difficult to find conditions suitable for handling and cryocooling the crystals before conducting X-ray diffraction experiments. To overcome this issue, a protein crystal-mounting method has been developed that involves a water-soluble polymer and controlled humid air that can adjust the moisture content of a mounted crystal. By coating crystals with polymer glue and exposing them to controlled humid air, the crystals were stable at room temperature and were cryocooled under optimized humidity. Moreover, the glue-coated crystals reproducibly showed gradual transformations of their lattice constants in response to a change in humidity; thus, using this method, a series of isomorphous crystals can be prepared. This technique is valuable when working on fragile protein crystals, including membrane proteins, and will also be useful for multi-crystal data collection.Keywords
This publication has 37 references indexed in Scilit:
- Room temperature femtosecond X-ray diffraction of photosystem II microcrystalsProceedings of the National Academy of Sciences of the United States of America, 2012
- Linking Crystallographic Model and Data QualityScience, 2012
- Accessing protein conformational ensembles using room-temperature X-ray crystallographyProceedings of the National Academy of Sciences of the United States of America, 2011
- The Catalytic Architecture of Leukotriene C4 Synthase with Two Arginine ResiduesJournal of Biological Chemistry, 2011
- Rapid model building of α-helices in electron-density mapsActa Crystallographica Section D-Structural Biology, 2010
- Improving diffraction by humidity control: a novel device compatible with X-ray beamlinesActa Crystallographica Section D-Structural Biology, 2009
- Hyperquenching for protein cryocrystallographyJournal of Applied Crystallography, 2006
- Pros and cons of cryocrystallography: should we also collect a room-temperature data set?Acta Crystallographica Section D-Structural Biology, 2004
- Macromolecular CryocrystallographyJournal of Applied Crystallography, 1997
- [20] Processing of X-ray diffraction data collected in oscillation modeMethods in Enzymology, 1997