Separation/Preconcentration of Xylenol Orange Metal Complexes on Amberlite XAD-16 Column for Their Determination by Flame Atomic Absorption Spectrometry
- 2 January 2003
- journal article
- Published by Taylor & Francis Ltd in Journal of Trace and Microprobe Techniques
- Vol. 21 (3), 455-466
- https://doi.org/10.1081/tma-120023062
Abstract
A separation and preconcentration method is described for the determination of copper, nickel, cobalt, lead, iron and cadmium in natural water and some salt samples by flame AAS. The analyte trace metal ions in the samples were sorbed as xylenol orange complexes on Amberlite XAD-16 column at the pH range of 7–9, and then eluted with 1M HNO3 in acetone. The effect of pH, reagent amount, sample volume, and matrix of the sample on the sorption of metal ions has also been investigated. The concentration of analyte ions detected after separation/and preconcentration was in agreement with the added amount of ions. The present method was found to be applicable to the preconcentration of analyte ions in natural water and some salt samples with good results such as relative standard deviations from 3 to 10% (N = 10).Keywords
This publication has 24 references indexed in Scilit:
- Speciation of Antimony Using Chromosorb 102 Resin as a Retention MediumAnalytical Sciences, 2003
- SEPARATION/PRECONCENTRATION OF Cu(II), Fe(III), Pb(II), Co(II), AND Cr(III) IN AQUEOUS SAMPLES ON CELLULOSE NITRATE MEMBRANE FILTER AND THEIR DETERMINATION BY ATOMIC ABSORPTION SPECTROMETRYAnalytical Letters, 2002
- Speciation of Fe(II) and Fe(III) by the modified ferrozine method, FIA–spectrophotometry, and flame AAS after cloud-point extractionAnalytical and Bioanalytical Chemistry, 2002
- Determination of total platinum in plasma and plasma ultrafiltrate, from subjects dosed with the platinum-containing N-(2-hydroxypropyl)methacrylamide copolymer AP5280, by use of graphite-furnace Zeeman atomic-absorption spectrometryAnalytical and Bioanalytical Chemistry, 2002
- ETAAS determination of nickel in serum and urineAnalytical and Bioanalytical Chemistry, 2002
- Evaluation of Several Gas Chromatographic Stationary Phases for the Solid-Phase Extraction of Trace Amounts of Copper in Aqueous SamplesAnalytical Sciences, 2002
- STATUS OF REFERENCE MATERIALS PROGRAMME IN INDIAJournal of Trace and Microprobe Techniques, 2002
- TRACE ELEMENT ESTIMATION IN SOILS: AN APPRAISAL OF ED-XRF TECHNIQUE USING GROUP ANALYSIS SCHEMEJournal of Trace and Microprobe Techniques, 2002
- Solid phase extraction of ultra trace copper(II) using octadecyl silica membrane disks modified by a naphthol-derivative Schiff’s baseAnalytica Chimica Acta, 2000
- Adsorption of Metallic Cations on Silica Gel-Immobilized 8-HydroxyquinolineSeparation Science and Technology, 2000