Abstract
BACKGROUND AND PURPOSE: MR including MRV is an established method to diagnose CVT. However, it remains unsettled which MR imaging modalities offer the highest diagnostic accuracy. We evaluated the accuracy of a combined, dynamic (1.5 seconds per dataset) and static (voxel size, 1.1 × 0.9 × 1.5 mm), contrast-enhanced MRV method (combo-4D MRV) relative to other established MR/MRV modalities. MATERIALS AND METHODS: A total of 39 patients with CVT (n = 20) and control subjects (n = 19) underwent combo-4D MRV, 2D TOF MRV, GRE imaging, and T2W imaging. For these modalities, diagnostic accuracy (ROCs) for CVT affecting 53 out of 234 predefined venous segments was determined. Sensitivity and specificity were separately calculated for different stages of CVT (acute/subacute/chronic). RESULTS: Combo-4D MRV showed the highest accuracy (AUC, 0.99 [95% CI, 0.97–1.0]; sensitivity, 97% [84%–100%]) for thrombosed dural sinuses. For all thrombosed segments including cortical veins, its sensitivity was best (76% [64%–84%]; AUC, 0.92 [0.88–0.96]), followed by TOF MRV (72% [59%–81%]; AUC, 0.93 [0.88–0.97]). Even for chronic CVT, it showed a relatively high sensitivity of 67% (30%–90%). For thrombosed cortical veins alone, GRE images achieved the highest sensitivity (66% [46%–81%]; AUC, 0.88 [0.78–0.97]). Specificities of all modalities ranged from 96% to 99%. CONCLUSIONS: Combo-4D MRV showed an excellent accuracy for the diagnosis of dural sinus thrombosis. The analysis of dynamic patterns of contrast enhancement in dural sinuses appeared useful to identify chronic thrombosis. To diagnose thrombosed cortical veins, GRE images should primarily be analyzed.Keywords
This publication has 22 references indexed in Scilit:
- Display of Dural Sinuses with Time-Resolved, Contrast-Enhanced Three-Dimensional MR VenographyCerebrovascular Diseases, 2008
- Cerebral Arteriovenous Malformation: Spetzler-Martin Classification at Subsecond-Temporal-Resolution Four-dimensional MR Angiography Compared with That at DSARadiology, 2008
- High-Spatial-Resolution Contrast-enhanced MR Angiography of the Intracranial Venous System with Fourfold Accelerated Two-dimensional Sensitivity Encoding1Radiology, 2007
- Cerebral venous thrombosis: an updateThe Lancet Neurology, 2007
- Imaging of Cerebral Venous Thrombosis: Current Techniques, Spectrum of Findings, and Diagnostic PitfallsRadioGraphics, 2006
- MRI of Clot in Cerebral Venous ThrombosisStroke, 2006
- Time-resolved 3D contrast-enhanced MRA with GRAPPA on a 1.5-T system for imaging of craniocervical vascular disease: initial experienceNeuroradiology, 2006
- Thrombosis of the Cerebral Veins and SinusesThe New England Journal of Medicine, 2005
- Three-dimensional Venography of the Brain with a Volumetric Interpolated SequenceRadiology, 2005
- Intracranial Venous System: Gadolinium-enhanced Three-dimensional MR Venography with Auto-triggered Elliptic Centric-ordered Sequence—Initial ExperienceRadiology, 2003