Display of Dural Sinuses with Time-Resolved, Contrast-Enhanced Three-Dimensional MR Venography
- 24 January 2008
- journal article
- research article
- Published by S. Karger AG in Cerebrovascular Diseases
- Vol. 25 (3), 217-224
- https://doi.org/10.1159/000113859
Abstract
Background: Time-resolved (TR) contrast-enhanced 3D MR angiography has recently received considerable attention for the workup of cerebrovascular diseases, foremost dural arteriovenous fistula and arteriovenous malformation, and potentially for the evaluation of dural sinus thrombosis. Thereby, the dynamic visualization of cerebral vessels is enabled similar to the principle of digital subtraction angiography. Yet, its voxel size is relatively large due to an inherent trade-off between the desired spatial and temporal resolutions. The goal of this study was to evaluate whether the limited spatial resolution of TR MR venography (MRV) is sufficient to visualize dural venous sinuses. Methods: The prospective study included 20 patients without compromise of cerebral venous outflow. Two neuroradiologists independently graded the quality of visualization of 11 predefined dural venous sinuses on images of fast TR contrast-enhanced MRV (1.5 s/dataset; voxel size, 2 × 2 × 2.2 mm; acquisition time, 37.5 s) in comparison to time-of-flight (TOF) MRV (voxel size, 0.8 × 0.8 × 4 mm; acquisition time, 3 min 51 s) and steady-state contrast-enhanced 3D (VIBE) MRV (voxel size, 1.1 × 0.9 × 1.5 mm; acquisition time, 2 min 46 s). Results: The torcular Herophili (p < 0.001), left (p < 0.001) and right (p < 0.01) transverse sinus, and right jugular bulb (p < 0.05) were visualized better at TR MRV than at TOF MRV. For visualization of the small inferior sagittal sinus, TR MRV was inferior to VIBE (p < 0.001) and TOF (p < 0.05) sequences. The visibility of all other dural sinuses was equal. Conclusion: Despite the inferior spatial resolution, TR MRV depicted some large dural sinuses more clearly than TOF MRV. To overcome the visualization of smaller venous structures, TR MRV can be applied complementarily with high-resolution steady-state contrast-enhanced MRV.This publication has 22 references indexed in Scilit:
- Cerebral venous thrombosis: an updateThe Lancet Neurology, 2007
- MRI of Clot in Cerebral Venous ThrombosisStroke, 2006
- Time-resolved 3D contrast-enhanced MRA with GRAPPA on a 1.5-T system for imaging of craniocervical vascular disease: initial experienceNeuroradiology, 2006
- Thrombosis of the Cerebral Veins and SinusesThe New England Journal of Medicine, 2005
- Importance of Anatomical Asymmetries of Transverse Sinuses: An MR Venographic StudyCerebrovascular Diseases, 2004
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- Preliminary experience with dynamic MR projection angiography in the evaluation of cervicocranial steno-occlusive diseaseEuropean Radiology, 2001
- Cerebral Dural Arteriovenous FistulasAmerican Journal of Roentgenology, 2000
- MR Angiography of the Intracranial Venous SystemRadiology, 2000
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999