Filter quality of electret masks in filtering 14.6–594 nm aerosol particles: Effects of five decontamination methods
Open Access
- 12 October 2017
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (10), e0186217
- https://doi.org/10.1371/journal.pone.0186217
Abstract
This study investigates the effects of five decontamination methods on the filter quality (qf) of three commercially available electret masks—N95, Gauze and Spunlace nonwoven masks. Newly developed evaluation methods, the overall filter quality (qf,o) and the qf ratio were applied to evaluate the effectiveness of decontamination methods for respirators. A scanning mobility particle sizer is utilized to measure the concentration of polydispersed particles with diameter 14.6–594 nm. The penetration of particles and pressure drop (Δp) through the mask are used to determine qf and qf,o. Experimental results reveal that the most penetrating particle size (MPS) for the pre-decontaminated N95, Gauze and Spunlace masks were 118 nm, 461 nm and 279 nm, respectively, and the respective penetration rates were 2.6%, 23.2% and 70.0%. The Δp through the pretreated N95 masks was 9.2 mm H2O at the breathing flow rate of heavy-duty workers, exceeding the Δp values obtained through Gauze and Spunlace masks. Decontamination increased the sizes of the most penetrating particles, changing the qf values of all of the masks: qf fell as particle size increased because the penetration increased. Bleach increased the Δp of N95, but destroyed the Gauze mask. However, the use of an autoclave reduces the Δp values of both the N95 and the Gauze mask. Neither the rice cooker nor ethanol altered the Δp of the Gauze mask. Chemical decontamination methods reduced the qf,o values for the three electret masks. The value of qf,o for PM0.1 exceeded that for PM0.1–0.6, because particles smaller than 100 nm had lower penetration, resulting in a better qf for a given pressure drop. The values of qf,o, particularly for PM0.1, reveal that for the tested treatments and masks, physical decontamination methods are less destructive to the filter than chemical methods. Nevertheless, when purchasing new or reusing FFRs, penetration should be regarded as the priority.Keywords
This publication has 16 references indexed in Scilit:
- Impact of Low Filter Resistances on Subjective and Physiological Responses to Filtering Facepiece RespiratorsPLOS ONE, 2013
- Factors Affecting Filter Penetration and Quality Factor of Particulate RespiratorsAerosol and Air Quality Research, 2013
- Impact of Three Biological Decontamination Methods on Filtering Facepiece Respirator Fit, Odor, Comfort, and Donning EaseJournal of Occupational and Environmental Hygiene, 2011
- Evaluation of Five Decontamination Methods for Filtering Facepiece RespiratorsAnnals of Occupational Hygiene, 2009
- Figure of Merit of Composite Filters with Micrometer and Nanometer FibersAerosol Science and Technology, 2008
- Infection Control and SARS Transmission among Healthcare Workers, TaiwanEmerging Infectious Diseases, 2004
- Control Measures for Severe Acute Respiratory Syndrome (SARS) in TaiwanEmerging Infectious Diseases, 2003
- The Effects of Particle Charge on the Performance of a Filtering FacepieceAihaj Journal, 1998
- Collection of three bacterial aerosols by respirator and surgical mask filters under varying conditions of flow and relative humidityAnnals of Occupational Hygiene, 1997
- Mycobacterial Aerosol Collection Efficiency of Respirator and Surgical Mask Filters under Varying Conditions of Flow and HumidityApplied Occupational and Environmental Hygiene, 1997