Abstract
Purpose To deploy clinically, a combined parallel imaging compressed sensing method with coil compression that achieves a rapid image reconstruction, and assess its clinical performance in contrast‐enhanced abdominal pediatric MRI. Materials and Methods With Institutional Review Board approval and informed patient consent/assent, 29 consecutive pediatric patients were recruited. Dynamic contrast‐enhanced MRI was acquired on a 3 Tesla scanner using a dedicated 32‐channel pediatric coil and a three‐dimensional SPGR sequence, with pseudo‐random undersampling at a high acceleration (R = 7.2). Undersampled data were reconstructed with three methods: a traditional parallel imaging method and a combined parallel imaging compressed sensing method with and without coil compression. The three sets of images were evaluated independently and blindly by two radiologists at one siting, for overall image quality and delineation of anatomical structures. Wilcoxon tests were performed to test the hypothesis that there was no significant difference in the evaluations, and interobserver agreement was analyzed. Results Fast reconstruction with coil compression did not deteriorate image quality. The mean score of structural delineation of the fast reconstruction was 4.1 on a 5‐point scale, significantly better (P < 0.05) than traditional parallel imaging (mean score 3.1). Fair to substantial interobserver agreement was reached in structural delineation assessment. Conclusion A fast combined parallel imaging compressed sensing method is feasible in a pediatric clinical setting. Preliminary results suggest it may improve structural delineation over parallel imaging. J. Magn. Reson. Imaging 2014;40:13–25.Keywords
This publication has 21 references indexed in Scilit:
- Coil compression for accelerated imaging with Cartesian samplingMagnetic Resonance in Medicine, 2012
- Fast $\ell_1$-SPIRiT Compressed Sensing Parallel Imaging MRI: Scalable Parallel Implementation and Clinically Feasible RuntimeIEEE Transactions on Medical Imaging, 2012
- Advances in pediatric body MRIPediatric Radiology, 2011
- Improved Pediatric MR Imaging with Compressed SensingRadiology, 2010
- SPIRiT: Iterative self‐consistent parallel imaging reconstruction from arbitrary k‐spaceMagnetic Resonance in Medicine, 2010
- A 128‐channel receive‐only cardiac coil for highly accelerated cardiac MRI at 3 TeslaMagnetic Resonance in Medicine, 2008
- Deep sedation and minimal anesthesiaPediatric Anesthesia, 2007
- Array compression for MRI with large coil arraysMagnetic Resonance in Medicine, 2007
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999