Preliminary Studies on Peripheral Nerve Regeneration using a New Polyurethane Conduit
- 1 March 2007
- journal article
- Published by SAGE Publications in Journal of Bioactive and Compatible Polymers
- Vol. 22 (2), 143-159
- https://doi.org/10.1177/0883911506076063
Abstract
There is currently interest in the use of tube-shaped nerve guides to induce regeneration of severed peripheral nerve axons, to assist nerve growth in the correct directions and to provide protection for the regenerating nerves. In the present paper, preliminary studies on the degradation and biocompatibility of a new elastomeric polyurethane (PU), based on polycaprolactone, polyethylene glycol and 1,6-hexamethyl diisocyanate. The PU elastomer was evaluated in vivo for the repair of a 12-mm femoral nerve gap in rabbits. Histological and scanning electron microscope observations were carried out at three days and then 4, 8, 10 and 12 weeks postoperation. Electrophysiological recording was performed six months postoperation. Myelinated axon regeneration was observed from four weeks after implantation. Polymer degradation was observed over the duration of the study. The results suggest that PU channels can be used for the regeneration of peripheral nerves and are suitable for tissue engineering.Keywords
This publication has 22 references indexed in Scilit:
- Growth factor enhancement of peripheral nerve regeneration through a novel synthetic hydrogel tubeJournal of Neurosurgery, 2003
- Development of a Bioartificial Nerve Graft. II. Nerve Regeneration in VitroBiotechnology Progress, 2002
- Regeneration of canine peroneal nerve with the use of a polyglycolic acid–collagen tube filled with laminin‐soaked collagen sponge: a comparative study of collagen sponge and collagen fibers as filling materials for nerve conduitsJournal of Biomedical Materials Research, 2001
- A Polymer Foam Conduit Seeded with Schwann Cells Promotes Guided Peripheral Nerve RegenerationTissue Engineering, 2000
- Tubular versus conventional repair of median and ulnar nerves in the human forearm: Early results from a prospective, randomized, clinical studyThe Journal of Hand Surgery, 1997
- Tubular Repair of the Median Nerve in the Human ForearmJournal of Hand Surgery (European Volume), 1994
- Nerve regeneration and reinnervation after limb amputation and replantation: Clinical and physiological findingsMuscle & Nerve, 1990
- Complications from silicon‐polymer intubulation of nervesMicrosurgery, 1989
- An Alternative to the Classical Nerve Graft for the Management of the Short Nerve GapPlastic and Reconstructive Surgery, 1988
- Peripheral nerve regeneration with entubulation repair: Comparison of biodegradeable nerve guides versus polyethylene tubes and the effects of a laminin-containing gelExperimental Neurology, 1987