Four-Year Impact of an Alert Notification System on Closed-Loop Communication of Critical Test Results
- 1 November 2014
- journal article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 203 (5), 933-938
- https://doi.org/10.2214/ajr.14.13064
Abstract
OBJECTIVE. One of the patient safety goals proposed by the Joint Commission urges hospitals to develop a policy for communicating critical test results and to measure adherence to that policy. We evaluated the impact of an alert notification system on policy adherence for communicating critical imaging test results to referring providers and assessed system adoption over the first 4 years after implementation. MATERIALS AND METHODS. This study was performed in a 753-bed academic medical center. The intervention, an automated alert notification system for critical results, was implemented in January 2010. The primary outcome was adherence to institutional policy for timely closed-loop communication of critical imaging results, and the secondary outcome was system adoption. Policy adherence was determined through manual review of a random sample of radiology reports from the first 4 years after the intervention (n = 37,604) compared with baseline outcomes 1 year before the intervention (n = 9430). Adoption was evaluated by quantifying the use of the system overall and the proportion of alerts that used noninterruptive communication as a percentage of all reports generated by 320 radiologists (n = 1,538,059). A statistical analysis of the trend at 6-month intervals over 4 years was performed using a chi-square trend test. RESULTS. Adherence to the policy increased from 91.3% before the intervention to 95.0% after the intervention (p < 0.0001). There was a ninefold increase in the critical results communicated via the system (chi-square trend test, p < 0.0001). During the first 4 years after the intervention, 41,445 alerts (41% of the total number of alerts) used the system's noninterruptive process for communicating less urgent critical results, which was substantially unchanged over the 4 years postintervention, thus reducing unnecessary paging interruptions. CONCLUSION. An automated alert notification system for communicating critical imaging results was successfully adopted and was associated with increased adherence to institutional policy for communicating critical test results and with reduced workflow interruptions.Keywords
This publication has 34 references indexed in Scilit:
- Retrieval of Radiology Reports Citing Critical Findings with Disease-Specific CustomizationThe Open Medical Informatics Journal, 2012
- Information from Searching Content with an Ontology-Utilizing Toolkit (iSCOUT)Journal of Digital Imaging, 2012
- Lessons learned from implementation of a computerized application for pending tests at hospital dischargeJournal of Hospital Medicine, 2010
- Provider management strategies of abnormal test result alerts: a cognitive task analysisJournal of the American Medical Informatics Association, 2010
- Timely Follow-up of Abnormal Diagnostic Imaging Test Results in an Outpatient SettingArchives of Internal Medicine, 2009
- Developing a Radiology Quality and Safety Program: A PrimerRadioGraphics, 2009
- The unintended consequences of computerized provider order entry: Findings from a mixed methods explorationInternational Journal of Medical Informatics, 2009
- Business Intelligence Tools for Radiology: Creating a Prototype Model Using Open-Source ToolsJournal of Digital Imaging, 2008
- Medical Errors Involving TraineesArchives of Internal Medicine, 2007
- Communication Outcomes of Critical Imaging Results in a Computerized Notification SystemJournal of the American Medical Informatics Association, 2007