Design of Wearable Power Assist Wear for Low Back Support Using Pneumatic Actuators
- 5 March 2013
- journal article
- Published by Fuji Technology Press Ltd. in International Journal of Automation Technology
- Vol. 7 (2), 228-236
- https://doi.org/10.20965/ijat.2013.p0228
Abstract
This research focuses on developing a safe, lightweight, power assist device that can be worn by people during lifting or static holding tasks to prevent them from experiencing Low Back Pain (LBP). In consideration of their flexibility, light weight, and large force to weight ratio, two types of pneumatic actuators are employed in assisting low back movement for their safety and comfort. Actuator A is an elongation-type pneumatic rubber artificial muscle that is installed in the outer layer of the garment. Its two ends are fixed on the shoulders and thighs. It can output contractile force, assisting the erector spinae muscles in the same direction. Compared to McKibben-type pneumatic rubber artificial muscle, the elongation type has a larger contraction rate. Actuator B is a layer-type of pneumatic actuator; it is composed of two balloons, and it is installed in the inner layer of the garment. By taking into account the biomechanic structure of the human spine, this device can provide support in two ways. Actuator A acts as an external muscle power generators to reduce the force requirement for the erector spinae muscles. As actuator B acts as a moment arm of the contractile force generated by actuator A, it will increase the effective amount of torque. The device can be worn directly on the body like normal clothing. Because there is no rigid exoskeleton frame structure, it is lightweight and user friendly. The system’s Inertial Measurement Unit (IMU), composed of accelerometer sensors and gyro sensors to measure the human motion signals, can monitor the angles of the human body in real-time mode. By measuring the EMG signal of the human erector spinae muscles, the assistance effectiveness of the proposed device has been proven through experiments.Keywords
This publication has 11 references indexed in Scilit:
- Low Back Pain in Female Caregivers in Nursing HomesPublished by IntechOpen ,2012
- Quantitative Performance Analysis of Exoskeleton Augmenting Devices - Muscle Suit - for Manual WorkerInternational Journal of Automation Technology, 2011
- HAL: Hybrid Assistive Limb Based on CybernicsPublished by Springer Science and Business Media LLC ,2010
- Assist Force Control of Smart Suit for Horse Trainers Considering Motion SynchronizationInternational Journal of Automation Technology, 2009
- Development of Power Assist Wear Using Pneumatic Rubber Artificial MusclesJournal of Robotics and Mechatronics, 2009
- Mathematical and empirical proof of principle for an on-body personal lift augmentation device (PLAD)Journal of Biomechanics, 2007
- Wearable Power Assist Device for Standing Up Motion Using Pneumatic Rubber Artificial MusclesJournal of Robotics and Mechatronics, 2007
- Stand-Alone Wearable Power Assist Suit –Development and Availability–Journal of Robotics and Mechatronics, 2005
- Design of Wearable Power-Assist Device for Lower Back SupportJournal of Robotics and Mechatronics, 2004
- Lumbar spine stability can be augmented with an abdominal belt and/or increased intra-abdominal pressureEuropean Spine Journal, 1999