Inherent Variability of CT Lung Nodule Measurements In Vivo Using Semiautomated Volumetric Measurements
- 1 April 2006
- journal article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 186 (4), 989-994
- https://doi.org/10.2214/ajr.04.1821
Abstract
OBJECTIVE. The objective of our study was to evaluate repeatability and reproducibility of lung nodule volume measurements using volumetric nodule-sizing software. MATERIALS AND METHODS. Fifty nodules, less than 20 mm in diameter, in 29 patients were scanned with 1.25-mm collimation using MDCT (time 1 = T1). During the same session, two additional scans, using identical technique, were obtained through each nodule (T2, T3). Three observers working independently then obtained volumetric measurements using a semiautomated volumetric nodule-sizing software package. Qualitative nodule characterization was also performed. The Bland-Altman method for assessing measurement agreement was used to calculate the 95% limits for agreement for nodule volumes at T1, T2, and T3. RESULTS. Automated nodule segmentation was successful in 438 (97%) of 450 measurements. Forty-three nodules were available for final evaluation. Twenty-six nodules had well-defined edges, and 17 had irregular or spiculated margins. Seventeen were freestanding, 16 were juxtapleural, and 10 were juxtavascular in location. Average nodule volume was 345.5 mm3 (range, 49.3–1,434 mm3). The mean interobserver variability (repeatability) was 0.018% (SD = 0.73%), and the SD of the mean for the three contemporaneous scans (reproducibility) was 13.1% (confidence limits, ± 25.6%). SD and confidence limits narrowed as volumes increased. CONCLUSION. Volumetric measurements show minimal interobserver variability (0.018%) but an interscan SEM of 13.1% (confidence limits, ± 25.6%). Repeatability and reproducibility of volumetric measurements are better than those of linear measurements reported in the literature.Keywords
This publication has 18 references indexed in Scilit:
- Volumetric Assessment of Pulmonary Nodules with ECG-Gated MDCTAmerican Journal of Roentgenology, 2004
- Are Two-dimensional CT Measurements of Small Noncalcified Pulmonary Nodules Reliable?Radiology, 2004
- Effect of Varying CT Section Width on Volumetric Measurement of Lung Tumors and Application of Compensatory EquationsRadiology, 2003
- Screening for Lung Cancer with Low-Dose Spiral Computed TomographyAmerican Journal of Respiratory and Critical Care Medicine, 2002
- Chest CT: Automated Nodule Detection and Assessment of Change over Time—Preliminary ExperienceRadiology, 2001
- Growth rate of small lung cancers detected on mass CT screening.The British Journal of Radiology, 2000
- Small Pulmonary Nodules: Volumetrically Determined Growth Rates Based on CT EvaluationRadiology, 2000
- Evaluation of Tumor Measurements in Oncology: Use of Film-Based and Electronic TechniquesJournal of Clinical Oncology, 2000
- Spiral CT of pulmonary nodules: interobserver variation in assessment of lesion sizeEuropean Radiology, 2000
- The effect on apparent size of simulated pulmonary nodules of using three standard CT window settingsClinical Radiology, 1993