Integration and calibration of non-dispersive infrared (NDIR) CO2 low-cost sensors and their operation in a sensor network covering Switzerland
Open Access
- 15 July 2020
- journal article
- research article
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 13 (7), 3815-3834
- https://doi.org/10.5194/amt-13-3815-2020
Abstract
More than 300 non-dispersive infrared (NDIR) CO2 low-cost sensors labelled as LP8 were integrated into sensor units and evaluated for the purpose of long-term operation in the Carbosense CO2 sensor network in Switzerland. Prior to deployment, all sensors were calibrated in a pressure and climate chamber and in ambient conditions co-located with a reference instrument. To investigate their long-term performance and to test different data processing strategies, 18 sensors were deployed at five locations equipped with a reference instrument after calibration. Their accuracy during 19 to 25 months deployment was between 8 and 12 ppm. This level of accuracy requires careful sensor calibration prior to deployment, continuous monitoring of the sensors, efficient data filtering, and a procedure to correct drifts and jumps in the sensor signal during operation. High relative humidity (> ∼85 %) impairs the LP8 measurements, and corresponding data filtering results in a significant loss during humid conditions. The LP8 sensors are not suitable for the detection of small regional gradients and long-term trends. However, with careful data processing, the sensors are able to resolve CO2 changes and differences with a magnitude larger than about 30 ppm. Thereby, the sensor can resolve the site-specific CO2 signal at most locations in Switzerland. A low-power network (LPN) using LoRaWAN allowed for reliable data transmission with low energy consumption and proved to be a key element of the Carbosense low-cost sensor network.Keywords
This publication has 17 references indexed in Scilit:
- Characterization of a commercial lower-cost medium-precision non-dispersive infrared sensor for atmospheric CO2 monitoring in urban areasAtmospheric Chemistry and Physics, 2019
- Use of networks of low cost air quality sensors to quantify air quality in urban settingsAtmospheric Environment, 2018
- Performance of NO, NO2 low cost sensors and three calibration approaches within a real world applicationAtmospheric Chemistry and Physics, 2018
- The BErkeley Atmospheric CO2 Observation Network: field calibration and evaluation of low-cost air quality sensorsAtmospheric Chemistry and Physics, 2018
- Design of an ozone and nitrogen dioxide sensor unit and its long-term operation within a sensor network in the city of ZurichAtmospheric Chemistry and Physics, 2017
- Evaluation and environmental correction of ambient CO2 measurements from a low-cost NDIR sensorAtmospheric Chemistry and Physics, 2017
- Can commercial low-cost sensor platforms contribute to air quality monitoring and exposure estimates?Environment International, 2017
- Measurements of greenhouse gases at Beromünster tall-tower station in SwitzerlandAtmospheric Chemistry and Physics, 2016
- The CarboCount CH sites: characterization of a dense greenhouse gas observation networkAtmospheric Chemistry and Physics, 2015
- Low-cost NDIR based sensor platform for sub-ppm gas detectionUrban Climate, 2014