Design of an ozone and nitrogen dioxide sensor unit and its long-term operation within a sensor network in the city of Zurich
Open Access
- 17 October 2017
- journal article
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 10 (10), 3783-3799
- https://doi.org/10.5194/amt-10-3783-2017
Abstract
This study focuses on the investigation and quantification of low-cost sensor performance in application fields such as the extension of traditional air quality monitoring networks or the replacement of diffusion tubes. For this, sensor units consisting of two boxes featuring NO2 and O3 low-cost sensors and wireless data transfer were engineered. The sensor units were initially operated at air quality monitoring sites for 3 months for performance analysis and initial calibration. Afterwards, they were relocated and operated within a sensor network consisting of six locations for more than 1 year. Our analyses show that the employed O3 and NO2 sensors can be accurate to 2–5 and 5–7 ppb, respectively, during the first 3 months of operation. This accuracy, however, could not be maintained during their operation within the sensor network related to changes in sensor behaviour. For most of the O3 sensors a decrease in sensitivity was encountered over time, clearly impacting the data quality. The NO2 low-cost sensors in our configuration exhibited better performance but did not reach the accuracy level of NO2 diffusion tubes (∼ 2 ppb for uncorrected 14-day average concentrations). Tests in the laboratory revealed that changes in relative humidity can impact the signal of the employed NO2 sensors similarly to changes in ambient NO2 concentration. All the employed low-cost sensors need to be individually calibrated. Best performance of NO2 sensors is achieved when the calibration models also include time-dependent parameters accounting for changes in sensor response over time. Accordingly, an effective procedure for continuous data control and correction is essential for obtaining meaningful data. It is demonstrated that linking the measurements from low-cost sensors to the high-quality measurements from routine air quality monitoring stations is an effective procedure for both tasks provided that time periods can be identified when pollutant concentrations can be accurately predicted at sensor locations.This publication has 10 references indexed in Scilit:
- Community Air Sensor Network (CAIRSENSE) project: evaluation of low-cost sensor performance in a suburban environment in the southeastern United StatesAtmospheric Chemistry and Physics, 2016
- Data Verification Tools for Minimizing Management Costs of Dense Air-Quality Monitoring NetworksEnvironmental Science & Technology, 2015
- Field calibration of a cluster of low-cost available sensors for air quality monitoring. Part A: Ozone and nitrogen dioxideSensors and Actuators B: Chemical, 2015
- Evaluation and calibration of Aeroqual series 500 portable gas sensors for accurate measurement of ambient ozone and nitrogen dioxideAtmospheric Environment, 2014
- The next generation of low-cost personal air quality sensors for quantitative exposure monitoringAtmospheric Chemistry and Physics, 2014
- The Changing Paradigm of Air Pollution MonitoringEnvironmental Science & Technology, 2013
- The use of electrochemical sensors for monitoring urban air quality in low-cost, high-density networksAtmospheric Environment, 2013
- Validation of low-cost ozone measurement instruments suitable for use in an air-quality monitoring networkMeasurement Science and Technology, 2013
- Amperometric Gas SensorsA ReviewChemical Reviews, 2008
- Personal sampler for nitrogen dioxideAihaj Journal, 1976