Objective: Auditory and vestibular outcomes after placement of a vestibular-cochlear implant in subjects with varying causes of vestibular loss. Study Design: Prospective case study. Setting: Tertiary referral center. Patients: Three human subjects received a vestibular cochlear implant. Subject 1 had sudden hearing and vestibular loss 10 years before implantation. Subjects 2 and 3 had bilateral Meniere's disease with resolution of acute attacks. All subjects had severe-profound deafness in the implanted ear and bilateral vestibular loss. Intervention: Vestibular-cochlear implant with electrode positions confirmed by CT. Main Outcome Measures: Electrically-evoked vestibular and cochlear compound action potentials (ECAPs), speech perception, and electrically-evoked slow-phase eye velocities. Results: Subject 1 had no vestibular ECAP, but normal cochlear ECAPs and cochlear implant function. She had minimal eye-movement with vestibular stimulation. Subject 2 had vestibular ECAPs. This subject had the largest eye velocities from electrical stimulation that we have seen in humans, exceeding 100 degrees per second. Her cochlear implant functions normally. Subject 3 had vestibular and cochlear ECAPs, and robust eye-movements and cochlear implant function. Conclusion: The etiology of vestibular loss appears to have a profound impact on sensitivity of vestibular afferents in distinction to cochlear afferents. If this dichotomy is common, it may limit the application of vestibular implants to diagnoses with preserved sensitivity of vestibular afferents. We speculate it is due to differences in topographic organization of Scarpa's versus the spiral ganglion. In two subjects, the second generation device can produce higher velocity eye movements than seen in the four subjects receiving the first-generation device.This publication has 15 references indexed in Scilit:
- United States multicenter clinical trial of the cochlear nucleus hybrid implant systemThe Laryngoscope, 2015
- Vestibular implantation and longitudinal electrical stimulation of the semicircular canal afferents in human subjectsJournal of Neurophysiology, 2015
- Longitudinal performance of an implantable vestibular prosthesisHearing Research, 2014
- Prosthetic Implantation of the Human Vestibular SystemOtology & Neurotology, 2014
- Postural responses to electrical stimulation of the vestibular end organs in human subjectsExperimental Brain Research, 2013
- Long‐Term Performance of Clarion 1.0 Cochlear Implant UsersThe Laryngoscope, 2007
- Histopathology of the Inner Ear Relevant to Cochlear ImplantationAdvances in oto-rhino-laryngology, 2006
- Performance over time of adult patients using the Ineraid or Nucleus cochlear implantThe Journal of the Acoustical Society of America, 1997
- Multivariate Predictors of Audiological Success with Multichannel Cochlear ImplantsAnnals of Otology, Rhinology & Laryngology, 1993
- Three‐Dimensional anatomy of human scarpa's ganglionThe Laryngoscope, 1992