Slover RH, Welsh JB, Criego A, Weinzimer SA, Willi SM, Wood MA, Tamborlane WV. Effectiveness of sensor‐augmented pump therapy in children and adolescents with type 1 diabetes in the STAR 3 study. Objective: Maintenance of appropriate A1C values and minimization of hyperglycemic excursions are difficult for many pediatric patients with type 1 diabetes. Continuous glucose monitoring (CGM) sensor‐augmented pump (SAP) therapy is an alternative to multiple daily injection (MDI) therapy in this population. Research design and methods: Sensor‐augmented pump therapy for A1C reduction (STAR 3) was a 1‐yr trial that included 82 children (aged 7–12) and 74 adolescents (aged 13–18) with A1C values ranging from 7.4 to 9.5% who were randomized to either SAP or MDI therapy. Quarterly A1C values were obtained from all subjects. CGM studies were carried out at baseline, 6 months, and 12 months to quantify glycemic excursions [calculated as area under the glucose concentration‐time curve (AUC)] and variability. In the SAP group, sensor compliance was recorded. Results: Baseline A1C values were similar in subjects randomized to the SAP (8.26 ± 0.55%) and MDI groups (8.30 ± 0.53%). All subsequent A1C values showed significant (p < 0.05) treatment group differences favoring SAP therapy. Compared with the MDI group, subjects in the SAP group were more likely to meet age‐specific A1C targets and had lower AUC values for hyperglycemia with no increased risk of hypoglycemia. Glucose variability improved in the SAP group compared to the MDI group. Children wore CGM sensors more often and were more likely to reach age‐specific A1C targets than adolescents. Conclusions: SAP therapy allows both children and adolescents with marginally or inadequately controlled type 1 diabetes to reduce A1C values, hyperglycemic excursions, and glycemic variability in a rapid, sustainable, and safe manner.Keywords
This publication has 11 references indexed in Scilit:
- Frequency of SMBG correlates with HbA1c and acute complications in children and adolescents with type 1 diabetesPediatric Diabetes, 2011
- Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 DiabetesNew England Journal of Medicine, 2010
- Continuous Glucose Monitoring in Youth with Type 1 Diabetes: 12-Month Follow-Up of the Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Randomized TrialDiabetes Technology & Therapeutics, 2010
- STAR 3 Randomized Controlled Trial to Compare Sensor-Augmented Insulin Pump Therapy with Multiple Daily Injections in the Treatment of Type 1 Diabetes: Research Design, Methods, and Baseline Characteristics of Enrolled SubjectsDiabetes Technology & Therapeutics, 2010
- Standards of Medical Care in Diabetes—2010Diabetes Care, 2010
- Effectiveness of Continuous Glucose Monitoring in a Clinical Care EnvironmentDiabetes Care, 2009
- Factors Predictive of Use and of Benefit From Continuous Glucose Monitoring in Type 1 DiabetesDiabetes Care, 2009
- Glycaemic control with continuous subcutaneous insulin infusion compared with intensive insulin injections in patients with type 1 diabetes: meta-analysis of randomised controlled trialsBMJ, 2002
- Effect of intensive diabetes treatment on the development and progression of long-term complications in adolescents with insulin-dependent diabetes mellitus: Diabetes Control and Complications TrialThe Journal of Pediatrics, 1994
- The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes MellitusNew England Journal of Medicine, 1993