Dual hypothermic oxygenated machine perfusion in liver transplants donated after circulatory death
Top Cited Papers
Open Access
- 10 April 2017
- journal article
- research article
- Published by Oxford University Press (OUP) in British Journal of Surgery
- Vol. 104 (7), 907-917
- https://doi.org/10.1002/bjs.10515
Abstract
Background Experimental studies have suggested that end-ischaemic dual hypothermic oxygenated machine perfusion (DHOPE) may restore hepatocellular energy status and reduce reperfusion injury in donation after circulatory death (DCD) liver grafts. The aim of this prospective case–control study was to assess the safety and feasibility of DHOPE in DCD liver transplantation. Methods In consecutive DCD liver transplantations, liver grafts were treated with end-ischaemic DHOPE. Outcome was compared with that in a control group of DCD liver transplantations without DHOPE, matched for donor age, donor warm ischaemia time, and recipient Model for End-stage Liver Disease (MELD) score. All patients were followed for 1 year. Results Ten transplantations involving liver grafts treated with DHOPE were compared with 20 control procedures. There were no technical problems. All 6-month and 1-year graft and patient survival rates were 100 per cent in the DHOPE group. Six-month graft survival and 1-year graft and patient survival rates in the control group were 80, 67 and 85 per cent respectively. During DHOPE, median (i.q.r.) hepatic adenosine 5′-triphosphate (ATP) content increased 11-fold, from 6 (3–10) to 66 (42–87) µmol per g protein (P = 0·005). All DHOPE-preserved livers showed excellent early function. At 1 week after transplantation peak serum alanine aminotransferase (ALT) and bilirubin levels were twofold lower in the DHOPE group than in the control group (ALT: median 966 versus 1858 units/l respectively, P = 0·006; bilirubin: median 1·0 (i.q.r. 0·7–1·4) versus 2·6 (0·9–5·1) mg/dl, P = 0·044). None of the ten DHOPE-preserved livers required retransplantation for non-anastomotic biliary stricture, compared with five of 20 in the control group (P = 0·140). Conclusion This clinical study of end-ischaemic DHOPE in DCD liver transplantation suggests that the technique restores hepatic ATP, reduces reperfusion injury, and is safe and feasible. RCTs with larger numbers of patients are warranted to assess the efficacy in reducing post-transplant biliary complications.Keywords
This publication has 31 references indexed in Scilit:
- A meta-analysis and meta-regression of outcomes including biliary complications in donation after cardiac death liver transplantationTransplant International, 2014
- Hypothermic Oxygenated Machine Perfusion Prevents Arteriolonecrosis of the Peribiliary Plexus in Pig Livers Donated after Circulatory DeathPLOS ONE, 2014
- Hypothermic reconditioning by gaseous oxygen persufflation after cold storage of porcine kidneysCryobiology, 2012
- Excorporeal Normothermic Machine Perfusion Resuscitates Pig DCD Livers with Extended Warm IschemiaJournal of Surgical Research, 2012
- Biliary Complications After Liver Transplantation From Donation After Cardiac Death DonorsAnnals of Surgery, 2011
- Similar liver transplantation survival with selected cardiac death donors and brain death donorsBritish Journal of Surgery, 2010
- One Hour Hypothermic Oxygenated Perfusion (HOPE) Protects Nonviable Liver Allografts Donated After Cardiac DeathAnnals of Surgery, 2009
- Influence of Flow and Addition of Oxygen During Porcine Liver Hypothermic Machine PerfusionTransplantation Proceedings, 2007
- Novel Short-term Hypothermic Oxygenated Perfusion (HOPE) System Prevents Injury in Rat Liver Graft From Non-Heart Beating DonorAnnals of Surgery, 2006
- Rescue of the Cold Preserved Rat Liver by Hypothermic Oxygenated Machine PerfusionAmerican Journal of Transplantation, 2006