Stability of selected volatile breath constituents in Tedlar, Kynar and Flexfilm sampling bags
- 4 January 2013
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 138 (5), 1405-1418
- https://doi.org/10.1039/c2an36193k
Abstract
The stability of 41 selected breath constituents in three types of polymer sampling bags, Tedlar, Kynar, and Flexfilm, was investigated using solid phase microextraction and gas chromatography mass spectrometry. The tested molecular species belong to different chemical classes (hydrocarbons, ketones, aldehydes, aromatics, sulphurs, esters, terpenes, etc.) and exhibit close-to-breath low ppb levels (3–12 ppb) with the exception of isoprene, acetone and acetonitrile (106 ppb, 760 ppb, 42 ppb respectively). Stability tests comprised the background emission of contaminants, recovery from dry samples, recovery from humid samples (RH 80% at 37 °C), influence of the bag's filling degree, and reusability. Findings yield evidence of the superiority of Tedlar bags over remaining polymers in terms of background emission, species stability (up to 7 days for dry samples), and reusability. Recoveries of species under study suffered from the presence of high amounts of water (losses up to 10%). However, only heavier volatiles, with molecular masses higher than 90, exhibited more pronounced losses (20–40%). The sample size (the degree of bag filling) was found to be one of the most important factors affecting the sample integrity. To sum up, it is recommended to store breath samples in pre-conditioned Tedlar bags up to 6 hours at the maximum possible filling volume. Among the remaining films, Kynar can be considered as an alternative to Tedlar; however, higher losses of compounds should be expected even within the first hours of storage. Due to the high background emission Flexfilm is not suitable for sampling and storage of samples for analyses aiming at volatiles at a low ppb level.Keywords
This publication has 34 references indexed in Scilit:
- Lung cancer biomarkers in exhaled breathExpert Review of Molecular Diagnostics, 2011
- Progress in SIFT‐MS: Breath analysis and other applicationsMass Spectrometry Reviews, 2011
- Physiological modeling of isoprene dynamics in exhaled breathJournal of Theoretical Biology, 2010
- Noninvasive detection of lung cancer by analysis of exhaled breathBMC Cancer, 2009
- The analysis of healthy volunteers' exhaled breath by the use of solid-phase microextraction and GC-MSJournal of Breath Research, 2008
- On the use of Tedlar® bags for breath-gas sampling and analysisJournal of Breath Research, 2008
- Detection of lung cancer using weighted digital analysis of breath biomarkersClinica Chimica Acta; International Journal of Clinical Chemistry, 2008
- The suitability of Tedlar bags for breath sampling in medical diagnostic researchPhysiological Measurement, 2006
- Diagnostic potential of breath analysis—focus on volatile organic compoundsClinica Chimica Acta; International Journal of Clinical Chemistry, 2004
- Investigation of Organic Vapor Losses to Condensed Water Vapor in Tedlar® Bags Used for Exhaled-Breath SamplingAihaj Journal, 1996