207-nm UV Light - A Promising Tool for Safe Low-Cost Reduction of Surgical Site Infections. I: In Vitro Studies
Open Access
- 16 October 2013
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (10), e76968
- https://doi.org/10.1371/journal.pone.0076968
Abstract
0.5% to 10% of clean surgeries result in surgical-site infections, and attempts to reduce this rate have had limited success. Germicidal UV lamps, with a broad wavelength spectrum from 200 to 400 nm are an effective bactericidal option against drug-resistant and drug-sensitive bacteria, but represent a health hazard to patient and staff. By contrast, because of its limited penetration, ∼200 nm far-UVC light is predicted to be effective in killing bacteria, but without the human health hazards to skin and eyes associated with conventional germicidal UV exposure. The aim of this work was to test the biophysically-based hypothesis that ∼200 nm UV light is significantly cytotoxic to bacteria, but minimally cytotoxic or mutagenic to human cells either isolated or within tissues. A Kr-Br excimer lamp was used, which produces 207-nm UV light, with a filter to remove higher-wavelength components. Comparisons were made with results from a conventional broad spectrum 254-nm UV germicidal lamp. First, cell inactivation vs. UV fluence data were generated for methicillin-resistant S. aureus (MRSA) bacteria and also for normal human fibroblasts. Second, yields of the main UV-associated pre-mutagenic DNA lesions (cyclobutane pyrimidine dimers and 6-4 photoproducts) were measured, for both UV radiations incident on 3-D human skin tissue. We found that 207-nm UV light kills MRSA efficiently but, unlike conventional germicidal UV lamps, produces little cell killing in human cells. In a 3-D human skin model, 207-nm UV light produced almost no pre-mutagenic UV-associated DNA lesions, in contrast to significant yields induced by a conventional germicidal UV lamp. As predicted based on biophysical considerations, 207-nm light kills bacteria efficiently but does not appear to be significantly cytotoxic or mutagenic to human cells. Used appropriately, 207-nm light may have the potential for safely and inexpensively reducing surgical-site infection rates, including those of drug-resistant origin.Keywords
This publication has 60 references indexed in Scilit:
- Balancing the Risk of Eye Irritation from UV‐C with Infection from BioaerosolsPhotochemistry and Photobiology, 2013
- Reduction of Surgical Site Infections after Implementation of a Bundle of CarePLOS ONE, 2012
- Ultraviolet C irradiation: an alternative antimicrobial approach to localized infections?Expert Review of Anti-infective Therapy, 2012
- UV wavelength-dependent DNA damage and human non-melanoma and melanoma skin cancerPhotochemical & Photobiological Sciences, 2011
- Upper-Room Ultraviolet Light and Negative Air Ionization to Prevent Tuberculosis TransmissionPLoS Medicine, 2009
- The determination of stratum corneum thickness An alternative approachEuropean Journal of Pharmaceutics and Biopharmaceutics, 2008
- Mutations induced by ultraviolet lightMutation Research, 2005
- Functional genomics of UV radiation responses in human cellsMutation Research, 2004
- Staphylococci, in vitro and in vivoDiagnostic Microbiology and Infectious Disease, 1985
- WAVELENGTH DEPENDENCE OF INACTIVATION AND MUTATION INDUCTION TO 6-THIOGUANINE-RESISTANCE IN V79 CHINESE HAMSTER FIBROBLASTSPhotochemistry and Photobiology, 1984