The use of pitch factor in calculations of AC-machines with concentrated windings
- 1 January 2005
- conference paper
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 5 pp.-P.5
- https://doi.org/10.1109/epe.2005.219314
Abstract
In AC-machines with concentrated, non-overlapping stator windings the calculation of the winding factor xi - especially the pitch factor xip is difficult as the coil embraces only one tooth. This paper attempts to verify several xip-choices using an uncommon approach with finite element (FE) analysis. The results match good with classical analytical xip calculation methodsKeywords
This publication has 3 references indexed in Scilit:
- A time decoding realization with a CNNPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2005
- Winding factors and Joule losses of permanent magnet machines with concentrated windingsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2003
- Computer-Aided Design in MagneticsPublished by Springer Science and Business Media LLC ,1986