Background—Quantification of mitral regurgitation severity with 2-dimensional (2D) imaging techniques remains challenging. The present study compared the accuracy of 2D transesophageal echocardiography (TEE) and 3-dimensional (3D) TEE for quantification of mitral regurgitation, using MRI as the reference method. Methods and Results—Two-dimensional and 3D TEE and cardiac MRI were performed in 30 patients with mitral regurgitation. Mitral effective regurgitant orifice area (EROA) and regurgitant volume (Rvol) were estimated with 2D and 3D TEE. With 3D TEE, EROA was calculated using planimetry of the color Doppler flow from en face views and Rvol was derived by multiplying the EROA by the velocity time integral of the regurgitant jet. Finally, using MRI, mitral Rvol was quantified by subtracting the aortic flow volume from left ventricular stroke volume. Compared with 3D TEE, 2D TEE underestimated the EROA by a mean of 0.13 cm2. In addition, 2D TEE underestimated the Rvol by 21.6% when compared with 3D TEE a...Keywords
This publication has 26 references indexed in Scilit:
- Direct Measurement of Vena Contracta Area by Real-Time 3-Dimensional Echocardiography for Assessing Severity of Mitral RegurgitationThe American Journal of Cardiology, 2009
- Three-Dimensional Color Doppler Echocardiography for Direct Measurement of Vena Contracta Area in Mitral RegurgitationJACC: Cardiovascular Imaging, 2008
- Direct Assessment of Size and Shape of Noncircular Vena Contracta Area in Functional Versus Organic Mitral Regurgitation Using Real-Time Three-Dimensional EchocardiographyJournal of the American Society of Echocardiography, 2008
- Is It Time to Update the Definition of Functional Mitral Regurgitation?Circulation, 2008
- In Vitro Validation of Real-Time Three-Dimensional Color Doppler Echocardiography for Direct Measurement of Proximal Isovelocity Surface Area in Mitral RegurgitationThe American Journal of Cardiology, 2007
- Comparison of Orifice Area by Transthoracic Three-Dimensional Doppler Echocardiography Versus Proximal Isovelocity Surface Area (PISA) Method for Assessment of Mitral RegurgitationThe American Journal of Cardiology, 2006
- How We Perform Cardiovascular Magnetic Resonance Flow Assessment Using Phase-Contrast Velocity MappingJournal of Cardiovascular Magnetic Resonance, 2005
- Quantitative Determinants of the Outcome of Asymptomatic Mitral RegurgitationNew England Journal of Medicine, 2005
- Three-dimensional reconstruction of color doppler flow convergence regions and regurgitant jets: An in vitro quantitative studyJournal of the American College of Cardiology, 1996
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986