Task Group 142 report: Quality assurance of medical acceleratorsa)
Top Cited Papers
- 17 August 2009
- journal article
- guideline
- Published by Wiley in Medical Physics
- Vol. 36 (9Part1), 4197-4212
- https://doi.org/10.1118/1.3190392
Abstract
The task group (TG) for quality assurance of medical accelerators was constituted by the American Association of Physicists in Medicine's Science Council under the direction of the Radiation Therapy Committee and the Quality Assurance and Outcome Improvement Subcommittee. The task group (TG-142) had two main charges. First to update, as needed, recommendations of Table II of the AAPM TG-40 report on quality assurance and second, to add recommendations for asymmetric jaws, multileaf collimation (MLC), and dynamic/virtual wedges. The TG accomplished the update to TG-40, specifying new test and tolerances, and has added recommendations for not only the new ancillary delivery technologies but also for imaging devices that are part of the linear accelerator. The imaging devices include x-ray imaging, photon portal imaging, and cone-beam CT. The TG report was designed to account for the types of treatments delivered with the particular machine. For example, machines that are used for radiosurgery treatments or intensity-modulated radiotherapy (IMRT) require different tests and/or tolerances. There are specific recommendations for MLC quality assurance for machines performing IMRT. The report also gives recommendations as to action levels for the physicists to implement particular actions, whether they are inspection, scheduled action, or immediate and corrective action. The report is geared to be flexible for the physicist to customize the QA program depending on clinical utility. There are specific tables according to daily, monthly, and annual reviews, along with unique tables for wedge systems, MLC, and imaging checks. The report also gives specific recommendations regarding setup of a QA program by the physicist in regards to building a QA team, establishing procedures, training of personnel, documentation, and end-to-end system checks. The tabulated items of this report have been considerably expanded as compared with the original TG-40 report and the recommended tolerances accommodate differences in the intended use of the machine functionality (non-IMRT, IMRT, and stereotactic delivery).Keywords
This publication has 60 references indexed in Scilit:
- MLC quality assurance using EPID: A fitting technique with subpixel precisionMedical Physics, 2008
- An extensive log‐file analysis of step‐and‐shoot intensity modulated radiation therapy segment delivery errorsMedical Physics, 2004
- Leaf trajectory verification during dynamic intensity modulated radiotherapy using an amorphous silicon flat panel imagerMedical Physics, 2004
- Fast and accurate leaf verification for dynamic multileaf collimation using an electronic portal imaging deviceMedical Physics, 2002
- Characterizing output for dynamic wedgesMedical Physics, 1996
- Comprehensive analysis of electron beam central axis dose for a radiotherapy linear acceleratorMedical Physics, 1994
- A mono isocentric technique for breast and regional nodal therapy using dual asymmetric jawsInternational Journal of Radiation Oncology*Biology*Physics, 1994
- Evaluation of electron-beam uniformity during commissioning of a linear acceleratorMedical Physics, 1993
- Calibration frequency as determined by analysis of machine stabilityMedical Physics, 1989
- Dosimetric aspects of the therapeutic photon beams from a dual-energy linear acceleratorMedical Physics, 1988