Audibility and identification of auditory alarms in the operating room and intensive care unit
- 1 October 1993
- journal article
- research article
- Published by Taylor & Francis Ltd in Ergonomics
- Vol. 36 (10), 1159-1176
- https://doi.org/10.1080/00140139308967986
Abstract
The audibility and the identification of 23 auditory alarms in the intensive care unit (ICU) and 26 auditory alarms in the operating rooms (ORs) of a 214-bed Canadian teaching hospital were investigated. Digital tape recordings of the alarms were made and analysed using masked-threshold software developed at the Université de Montréal. The digital recordings were also presented to the hospital personnel responsible for monitoring these alarms on an individual basis in order to determine how many of the alarms they would be able to identify when they heard them. Several of the alarms in both areas of the hospital could mask other alarms in the same area, and many of the alarms in the operating rooms could be masked by the sound of a surgical saw or a surgical drill. The staff in the OR (anaesthetists, anaesthesia residents, and OR technologists) were able to identify a mean of between 10 and 15 of the 26 alarms found in their operating theatres. The ICU nurses were able to identify a mean of between 9 and 14 of the 23 alarms found in their ICU. Alarm importance was positively correlated with the frequency of alarm identification in the case of the OR, rho=0·411, but was not significantly correlated in the case of the ICU, rho=0·155. This study demonstrates the poor design of auditory warning signals in hospitals and the need for standardization of alarms on medical equipment.Keywords
This publication has 23 references indexed in Scilit:
- Perceived urgency and the anaesthetist: responses to common operating room monitor alarmsCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1991
- Proposed New Alarm Standards May Make a Bad Situation WorseAnesthesiology, 1991
- Auditory warning sounds in the work environmentPhilosophical Transactions of the Royal Society of London. B, Biological Sciences, 1990
- Affective responses to commercial and experimental auditory alarm signals for anaesthesia delivery and physiological monitoring equipmentJournal of Clinical Monitoring and Computing, 1988
- Focused auditory attention and frequency selectivityPerception & Psychophysics, 1987
- Localization of sound in rooms, III: Onset and duration effectsThe Journal of the Acoustical Society of America, 1986
- An Alarming ProblemAnesthesiology, 1986
- Ergonomics: Anaesthetists’ use of auditory alarms in the operating roomJournal of Clinical Monitoring and Computing, 1985
- Localization of sound in roomsThe Journal of the Acoustical Society of America, 1983
- An “Alarming” situation in the intensive therapy unitIntensive Care Medicine, 1983